MMB Web-UI (Web User Interface) Operations
Items
#
Partition Name
Power Control Status
Power Save Control
Power save Grace Period
Action reaching Power
Save

TABLE 1.75 [Power Management Setup] Window Buttons

Buttons
Apply
The setting of the Power Management Setup is changed.
Cancel
Returns to the original state without changing the setting of the Power Management Setup.
(1)
Menu Operation
[Partition] - [Power Management Setup]
(2)
Window Operations
1.
Set the items for changing the settings of the Power Management Setup and click the [Apply] button.
Set the connection.
[Message]
This section describes the messages to be displayed on this window.
Message Number
Setting completed.
I_00013
W_00426
Invalid values specified.
E_00098
Failed to get Partition Power Management.
E_00098
Failed to get the system configuration.
Displays number (0~3) to identify the partition. However displays only the
partitions registered by SB/IOU.
Displays the name given to the Partition.
Displays the operating state of power control status of each partition.
Normal:
Normal operating state. Shows that the operating rate
suppression function for limitation of the electric power consumption is not
working.
Power Saving: Shows that the operating rate is being suppressed
Valid/ invalid Power Saving function setting is executed in the partition unit.
Enable
Disable
The setting can be done only when System Power Save Control is Enable and
gray color is shown when System Power Saving Control is Disable.
Default is Enable
Sets shutdown waiting time in partition unit when the Limit threshold is
exceeded.
Specified in the range of 0 ~ 99 minutes.
Shows a valid item when Power Save Control of partition is Enable and shows
gray color when Disable.
Default is 5 minutes.
Executes the operation setting in the partition unit after the Limit threshold
excess stand-by time.
Continue: Continues operation for the partition under operation.
Partition Power Off: Power Off is done for the partition under operation.
Partition Force Power Off: Force Power Off is done for the partition under
operation.
Displays a valid item when Power Save Control of partition is Enable and
displays gray color in case of Disable.
Default is Partition Power Off