4
Using the Digital Multimeter Functions

Ohmmeter

The ohmmeter provides measurements for resistance, continuity test,
capacitance and diode test. The instrument automatically select the range
using auto- range. However, you can manually adjust the range of the
measurement, giving faster performance. Refer to
in this section for more detailed information.

Resistance Measurement

Disconnect power to the device or circuit under test and discharge all high voltage
WA R N I N G
capacitors to avoid electric shock and prevent possible damage to the instrument or
device under test while taking resistance measurement.
To perform resistance measurement, do the following instructions:
1 Press
2 Press F2 to access ohmmeter submenu.
3 In the ohmmeter submenu, press F1 to select the resistance
4 Connect the red test lead to the
5 Probe the test point of the circuit or device under test.
6 Read the resistance reading from the display. The display indicates the
7 To perform relative function, please refer to
100
button to access meter menu.
measurement from the pull- up menu.
test lead to the COM terminal.
proper decimal point, value and symbols.
section in this chapter.
"Auto- range Mode
input terminal and the black

"Relative Function

Agilent U1602B/U1604B User's and Service Guide