Table 28 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKX1x) (continued)
Message ID
YKX199I TSO
Table 29 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKX2x)
Message ID
YKX200T TSO RC=48
YKX201E MSG SC=48
YKX201E MSG SC=48
YKX201E MSG SC=48
YKX201E TSO RC=48
YKX201E MSG SC=48
YKX201E MSG SC=48
YKX201E MSG SC=48
YKX201E MSG SC=48
YKX202E TSO RC=48
YKX202E MSG SC=48
YKX203E MSG SC=48
YKX204E MSG SC=48
YKX208E MSG SC=48
Message Text
YKDELCMD command return
code=nnnn, reason code=rrrr
Message Text
Supplied parameters invalid
No command control address
CCA() supplied
No control unit# CU() supplied
No device# DEVN() supplied
No message MSG() supplied
No model SMODEL() supplied
No results STEM() supplied
No serial# SN() supplied
No serial# SSN() supplied
Messages MSG(stem) does not
include trailing "."
Results STEM(stem) does not
include trailing "."
Parameter combination is invalid
Device# DEVN() is not found
CCA() not valid hex
Explanation and Recommended Actions
Review the ROUTE and DAD parameters, route list
definition file, and command device definition file you
specified when executing the YKLOAD command.
The YKDELCMD command terminated with the return
code nnnn and the reason code rrrr.
Explanation and Recommended Actions
Invalid parameters are specified.
For details, see the reason code in the YKX299I
message that will appear after this message. For
reason codes, see IKJPARS in the TSO/E Programming
Services.
Nothing is assigned to the CCA parameter.
Nothing is assigned to the CU parameter.
Nothing is assigned to the DEVN parameter.
Nothing is assigned to the MSG parameter.
Nothing is assigned to the SMODEL parameter.
Nothing is assigned to the STEM parameter.
Nothing is assigned to the SN parameter.
Nothing is assigned to the SSN parameter.
The last character of the MSG parameter is not a
period.
stem
Stem name assigned to the MSG
parameter
The last character of the STEM parameter is not a
period.
stem
Stem name assigned to the STEM
parameter
The specified parameter combination is invalid.
For details about the combination of parameters, see
the description of the YKQRYDEV command in the HP
P9000 for Business Continuity Manager Software
Reference Guide.
The device specified in the DEVN parameter does not
exist, or a device other than DASD or a PAV ALIAS
volume has been specified.
The value specified in the CCA parameter is not in
hexadecimal format.
List of Messages
99