HP XP P9500 Manual page 14

Hp p9000 for business continuity manager software messages
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YK80x) (continued)
Message ID
YK8055I PRT CON
YK8056E PRT CON
YK8070E PRT
YK8071E PRT
YK8073E PRT
YK8074E PRT
14
Messages
Message Text
time BCM Monitor will
pause now for 'sleep-time'
minutes.
time Failed to execute
operator command.
time File Open error :
dd-name.
time File Close error :
dd-name.
time A GETMAIN error
occurred. return code=nnn.
time A FREEMAIN error
occurred. return code=nnn.
Explanation and Recommended Actions
BCM Monitor will go to sleep because the PAUSE action was
executed.
Entering the WAKEUP command resumes copy group monitoring
before the sleep time of sleep-time has elapsed.
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
sleep-time
Sleep duration
BCM Monitor failed to execute an operator command.
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
The file dd-name could not be opened.
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
dd-name
DD name of the file where the error occurred
The file dd-name could not be closed.
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
dd-name
DD name of the file where the error occurred
A GETMAIN error occurred. The program will stop running. Contact
technical support for assistance.
time
Message output time
This is only displayed when the output
destination is SYSTSPRT.
nnn (decimal number)
Return code of the GETMAIN macro
A FREEMAIN error occurred. The program will stop running.
Contact technical support for assistance.
time
Message output time

Advertisement

Table of Contents