Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKG2x) (continued)
Message ID
Message Text
YKJ208W TSO
Inconsistencies exist among
RC=8
the values used to specify
the secondary volume:
dd-name: rec#
YKJ209E TSO
Subconsistency group ID
RC=32
cannot be specified for a
copy-type Copy Group:
dd-name: rec#
YKJ210E TSO
The value specified for
RC=32
Number-of-Pairs exceeds the
range in which volumes
exist: Number-Of-Pairs:
dd-name: rec#
YKJ21 1E TSO
PVOL & SVOL of Hitachi
RC=32
ShadowImage™ for
Mainframe (BC Z) pair is in
the different storage system:
dd-name: rec#
Explanation and Recommended Actions
rec#
Number of the line in the file identified by
dd-name where the error was detected
The S-VOL specified with the device number differs from the S-VOL
specified with the storage system serial number, CU number, and
command control address number.
Although the copy group definition file was created, the settings
therein might contain an error.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
A subconsistency group ID is specified for a copy group of the copy
type identified by copy-type. No subconsistency group ID can be
specified if the copy type is Hitachi ShadowImage™ for Mainframe,
Hitachi TrueCopy™ for Mainframe, Hitachi TrueCopy™
Asynchronous for Mainframe, HP Storage Business Copy for
Mainframe, or HP Storage Continuous Access Synchronous for
Mainframe.
copy-type
Copy type
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
No volume exists in the range of the Number-Of-Pairs repetitions.
Number-Of-Pairs
Number of pair repetitions
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
A copy pair, which has a P-VOL storage system serial number and
an S-VOL storage system serial number that do not match, was
found in a copy group of copy type BC Z.
dd-name
DD name of the CSV file where the error was
detected
rec#
Number of the line in the file identified by
dd-name where the error was detected
List of Messages