Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKL0x) (continued)
Message ID
YKL077W MSG
SC=4 RC=4
(file:rec#)
YKL079E MSG
SC=44 RC=44
(result)
YKL080E MSG
SC=36 RC=36
(file:rec#)
YKL081W MSG
SC=16 RC=16
(pair-index)
60
Messages
Message Text
APIInfo Level=level invalid.
Supported level is v.r.m.
YKVSET program failure for:
name = value
More than two DiskDevice
Elements in CopyPair.
Unable to resolve primary
device address.
Explanation and Recommended Actions
rec#
Number of the line in the file identified by file
where the error was detected
The system does not recognize the Level attribute level of the
APIInfo element that exists on the line with the line number
identified by rec# in the file identified by file.
Check the indicated line, and then identify the cause of the
problem by referring to information contained in the XML document
type definitions, in the HP P9000 for Business Continuity Manager
Software Reference Guide.
file
Name of the XML file where the error was
detected
rec#
Number of the line in the file identified by file
where the error was detected
v.r.m
API level
For details about this value, see the information
about the XML document type definitions in the
HP P9000 for Business Continuity Manager
Software Reference Guide.
An attempt to assign the value value to the variable name failed
with the result value identified by result. This error can be caused
by an invalid value being specified for the STEM parameter.
Only two copy pair elements are allowed: the first element for the
P-VOL and the second element for the S-VOL.
Check the line with the line number identified by rec# in the file
identified by file, and then identify the cause of the problem by
referring to information contained in the XML document type
definitions, in the HP P9000 for Business Continuity Manager
Software Reference Guide.
file
Name of the XML file where the error was
detected
rec#
Number of the line in the file identified by file
where the error was detected
The YKLOAD program failed to resolve the unit number (device
address) of the P-VOL in the specified CopyPair. For configuration
definition, this process uses the Host Discovered Array object in
the primary device address domain. For other purposes, the current
host device address domain is used. The situation represented by
this message is not always fatal. Some CLI commands, such as
YKSUSPND, can be successfully executed by using only the S-VOL
unit address.
pair-index
See the pair index description in the explanation of the YKE003E
message.