Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKA0x) (continued)
Message ID
YKB002I TSO
YKB100E TSO
YKB101E TSO
YKB102E TSO
30
Messages
Message Text
No copy pair was
discovered.
Missing or invalid
parameter:
parameter-name
The specified PREFIX is
being used by another
program.
Error occurred during
execution.
Cmd=command-name
msg=message-text:
message-value:
message-severity
Explanation and Recommended Actions
8: An I/O error occurred in a volume within the
search range. The copy group definition file was
created for the volume that was successfully
detected.
44: The processing was cancelled due to an
error. The copy group definition file was not
created.
48: The command ended due to an invalid
parameter.
No copy pair was detected within the specified range. Check the
operating range and status of the copy pair that you want to
acquire, and execute the YKP2B command again. If the copy pair
status is SIMPLEX, the YKP2B command does not detect any copy
pair.
The parameter specification was invalid or missing.
Check the following, and then re-execute the command:
Make sure that the required parameter indicated by
parameter-name was specified.
Make sure that the value specified for the required parameter
indicated by parameter-name is valid.
Make sure that different device address domain (DAD) IDs for
the primary and secondary sites are specified for the DAD
parameter.
parameter-name
Name of the invalid or missing parameter
The specified prefix is being used by another program.
Check the value specified for the prefix.
An error occurred during execution of the YKP2B command.
See the explanation corresponding to the message ID of the error
message indicated by message-text and take appropriate action.
Also see the additional information indicated by message-value
and message-severity again, take appropriate action. If the problem
is not resolved, contact an HP service representative.
command-name
CLI command name
message-text
Error message
message-value
Additional information about the error message
If no additional information is available, a space
is displayed.
message-severity
Additional information about the error message
If no additional information is available, a space
is displayed.
The error messages message-text, message-value, and
message-severity are displayed in the TSO/E terminal. Depending