Table 66 Details of Error Codes EBxx (continued)
Error
Error Details
Code
M-JNLG differs from that for
R-JNLG.
A Cnt Ac-J Z copy pair cannot be
EB50
made because the specified
volume does not exist.
A Cnt Ac-J Z copy pair cannot be
EB51
made because the specified
S-VOL has PIN data.
A Cnt Ac-J Z copy pair cannot be
EB52
made because the specified
S-VOL cannot be accessed.
A Cnt Ac-J Z copy pair cannot be
EB53
made because the specified
S-VOL is blocked.
A Cnt Ac-J Z copy pair cannot be
EB56
made because the status of the
cache is abnormal.
A Cnt Ac-J Z copy pair cannot be
EB5B
made because the LDEV guard is
set for the specified P-VOL or
S-VOL.
A Cnt Ac-J Z copy pair cannot be
EB5D
made because the LDEV security
is set for the specified P-VOL or
S-VOL.
A Cnt Ac-J Z copy pair cannot be
EB5E
made because the S-VOL is not in
the SIMPLEX status. Alternatively,
a Cnt Ac-J Z copy pair cannot be
resynchronized because the
S-VOL is not in the suspend status.
A Cnt Ac-J Z copy pair cannot be
EB5F
made because the Cnt Ac-J Z
program product is not installed
on the secondary storage system.
A Cnt Ac-J Z copy pair cannot be
EB60
made because the capacities of
the P-VOL and S-VOL do not
match.
A Cnt Ac-J Z copy pair cannot be
EB61
made because the path between
the primary storage system and
the secondary storage system is
invalid.
A Cnt Ac-J Z copy pair cannot be
EB62
made because the specified
P-VOL is a command device.
A Cnt Ac-J Z copy pair cannot be
EB63
made because another journal
group pair has been already
made in the R-JNL group.
232 Storage System Sense Byte Information
Type of Error
BC Z
Cnt Ac-S Z
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
Not output
TCA
Cnt Ac-J Z
CMD
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
Output
Not output
PATH
Others