Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ28x) (continued)
Message ID
YKZ282E MSG SC=36
#1
RC=36
YKZ282E MSG SC=36
#1
RC=36
YKZ283T MSG SC=36
#
RC=36
YKZ284T MSG SC=36
#
RC=36
YKZ285I MSG SC=0
RC=0 (index)
142 Messages
Message Text
Primary device IFType does not
support CAJ.
Secondary device IFType does not
support CAJ.
subCTGroupID value null or invalid.
CAJ value null or invalid.
This command cannot be executed
without a port.
Explanation and Recommended Actions
models (or later) where the first two digits of the
IFType are X'04' or higher.
Cnt Ac-J Z cannot be used on a storage system that
has a P-VOL or uses the remote DKC control function.
#2
Use a device
that supports Cnt Ac-J Z. Also, if a
scan was not performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The Cnt Ac-J Z is used in a storage system where
the first two digits of the IFType are X'11' or higher.
Cnt Ac-J Z cannot be used on a storage system that
has an S-VOL or uses the remote DKC control
function.
#2
Use a device
that supports Cnt Ac-J Z. Also, if a
scan was not performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The Cnt Ac-J Z is used in a storage system where
the first two digits of the IFType are X'11' or higher.
subCTGroupID in the copy group structure is either
NULL or invalid.
Correct the configuration file, and then execute the
YKLOAD command.
value
REXX variable value
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
Cnt Ac-J Z_MirrorID in the copy group structure
is either NULL or invalid.
Correct the configuration file, and then execute the
YKLOAD command.
value
REXX variable value
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
The YKBLDPTH, YKDELPTH, and YKQRYPTH
commands cannot be executed for a logical path
without a port element both on primary and
secondary direction. Only the YKQRYPTH command
with a RESTRUCT parameter can be executed on a
logical path without a port element.

Advertisement