HP XP P9500 Manual page 152

Hp p9000 for business continuity manager software messages
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ40x) (continued)
Message ID
YKZ406E MSG SC=36
#1
RC=36
YKZ406E MSG SC=36
#1
RC=36
YKZ407E MSG SC=24
RC=24
152 Messages
Message Text
Primary device IFType does not
support EXCTG.
Secondary device IFType does not
support EXCTG.
An error occurred during suspension
of CAJ ATTIME. (CT ID=ii, R-JNL=jj,
GENID=gg, ATTSTS=aa, SISTS=ss,
URSTS=uu, CODE=eeee,
TIME=ATTIME-suspend-time)
Explanation and Recommended Actions
configure a container, use different numbers in one
of the pairs of C/T group ID and sub C/T group ID
which describe the journal group number.
jj (hexadecimal number)
The journal group number specified by the C/T group
ID (00-FF)
kk (hexadecimal number)
The journal group number specified by the sub C/T
group ID (00-FF)
#
If this message is output while the YKLOAD
command is being executed, the RC is 44.
EXCTG cannot be used on a storage system that has
a P-VOL or uses the remote DKC control function.
#2
Use a device
that supports EXCTG. Also, if a scan
has not been performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
EXCTG is used in a storage system where the first
two digits of the IFType are X'13' or higher.
EXCTG cannot be used on a storage system that has
a S-VOL or uses the remote DKC control function.
#2
Use a device
that supports EXCTG. Also, if a scan
has not been performed after the storage system
microcode was replaced, perform another scan.
IFType
IFType value
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
EXCTG is used in a storage system where the first
two digits of the IFType are X'13' or higher.
An error occurred while the suspend processing using
the CAJ ATTIME suspend function was being
performed.
Check the error information, and remove the cause
of the error. If necessary, also check the storage
system log. After that, use the YKSUSPND command
to cancel the ATTIME suspend time, and then acquire
a backup again. See
"Multi-line Messages Output
to SYSTSPRT" (page 159)
for details.
ii (hexadecimal number)
consistency group ID for BC Z (00-7F)
jj (hexadecimal number)
The journal group number specified for the sub
consistency group ID for the Cnt Ac-J Z that links with
BC Z (00-FF)
gg (hexadecimal number)