Table 3 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKC0x) (continued)
Message ID
YKC099I TSO
Table 4 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKD0x)
Message ID
YKD000T TSO
RC=48
YKD001E TSO
RC=48
YKD001E MSG
SC=48 RC=48
YKD002E MSG
SC=48 RC=48
YKD002E MSG
SC=48
YKD002E TSO
RC=48
YKD008E MSG
SC=48
YKD010E TSO
RC=40
YKD050E MSG
SC=36 RC=48
(attribute-value)
34
Messages
Message Text
YKSCAN command return
code=nnnn, reason code=rrrr
Message Text
Supplied parameters invalid
No message MSG() supplied
No results STEM() supplied
Copy Group STEM(stem)
does not include trailing "."
DEVN() value invalid
Messages MSG(stem) does
not include trailing "."
DEVN() not valid hex
REXX failure return
code=nnnn starting with
variable name
Invalid Copy Group attribute
name
Explanation and Recommended Actions
Check the disk configuration definition file after the scan is
complete. If the volume serial number is different from the one in
the actual configuration, re-execute the scan.
The YKSCAN command terminated with the return code nnnn and
the reason code rrrr.
This message is always displayed to indicate the return code and
the reason code.
nnnn
Maximum among the severity codes returned
during command execution
Explanation and Recommended Actions
Invalid parameters are specified.
For details, see the reason code in the YKD099I message that will
appear after this message. For reason codes, see IKJPARS in the
TSO/E Programming Services.
Nothing is assigned to the MSG parameter.
Nothing is assigned to the STEM parameter.
The last character of the STEM parameter is not a period.
stem
Stem name assigned to the STEM parameter
The value assigned to the DEVN parameter is invalid.
The last character of the MSG parameter is not a period.
stem
Stem name assigned to the MSG parameter
The value specified in the DEVN parameter is not in hexadecimal
format.
Access to the REXX variable identified by name failed.
For details about the return code, see IKJCT441 in the TSO/E
Programming Services.
nnnn
Error code returned upon REXX access
The specified copy group attribute value is invalid for this command.
Correct the value and then re-execute the command.
name
REXX variable name