HP XP P9500 Manual page 111

Hp p9000 for business continuity manager software messages
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKY6x) (continued)
Message ID
YKY699I CON
Message Text
AGENT FUNCTION ABEND
CODE=Sxxx Uxxxx
DATE=yy-mm-dd TIME=hh:mm:nn
ABENDED-MODULE=module-name
C-DATE=module-creation-date
BASE=bbbbbbbb DISP=dddd
[CALLING-MODULE=module-name
C-DATE=y'y'.m'm'.d'd'
BASE=bbbbbbbb DISP=dddd]
PSW=pppppppp pppppppp ILC=ll
INTC=xx
REGISTERS AT TIME OF FAILURE
GR 00-03 contents-of-register-0
contents-of-register- 1
contents-of-register-2
contents-of-register-3
GR 04-07 contents-of-register-4
contents-of-register-5
contents-of-register-6
contents-of-register-7
GR 08- 1 1 contents-of-register-8
contents-of-register-9
contents-of-register- 1 0
contents-of-register- 1 1
GR 12- 1 5 contents-of-register- 1 2
contents-of-register- 1 3
contents-of-register- 1 4
contents-of-register- 1 5
Explanation and Recommended Actions
Return code from the command that
the Business Continuity Manager
agent executed
text
Message (maintenance information)
that was output by the command
that the Business Continuity
Manager agent executed
The main task or subtask terminated abnormally during
the Business Continuity Manager agent processing. If
the task cannot be recovered, the Business Continuity
Manager agent will be terminated.
Contact the center administrator.
Sxxx
System completion code when the
task terminated abnormally
(hexadecimal)
Uxxxx
User completion code when the
task terminated abnormally
(decimal number)
yy-mm-dd
Date the task terminated
abnormally
hh:mm:nn
Time the task terminated
abnormally
module-name
Section name of the Business
Continuity Manager agent module
or the load module name
If the module cannot be identified,
UNKNOWN is displayed. When
UNKNOWN is displayed, the values
indicated by y'y'.m'm'.d'd' and
bbbbbbbb are not correct.
module-creation-date
y'y'.m'm'.d'd': Creation date of the
module indicated by module-name
y'y'/m'm'/d'd': Creation date of
the module indicated by
module-name
bbbbbbbb
Contents of the base register
dddd
ABENDED-MODULE: Location
where ABENDED-MODULE was
List of Messages
1 1 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000 for business continuity manager 6.6.1

Table of Contents