HP XP P9500 Manual page 157

Hp p9000 for business continuity manager software messages
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ41x) (continued)
Message ID
YKZ414E MSG SC=36
#1
RC=48
Message Text
Copygroup SUPFnc does not support
parameter-name.
Explanation and Recommended Actions
The function indicated by parameter-name cannot
be used.
#2
Use a device
that supports the parameter-name
function or configuration. Also, if scanning was not
performed after the storage system microcode was
replaced, perform another scan.
SUPFnc (hexadecimal number)
Value for the version of the
storage system support function
used in the copy group
parameter-name
Function or configuration that
cannot be used:
UR_CTTIMEMODE:
Consistency time mode for
Cnt Ac-J Z
TC_OPENMF: Open/MF
Consistency Preservation
Function for Cnt Ac-S Z
LinkageOption=HS: 2DC
configuration with
HyperSwap and Cnt Ac-J Z
AttimeSplitMode=QUICK:
Quick suspend mode for the
CAJ ATTIME suspend function
#1
If this message is output while the YKLOAD
command is being executed, the RC is 44.
#2
The following shows the storage system models
for which you can use the parameter-name:
Consistency time mode for Cnt Ac-J Z
XP12000/XP10000 disk array
Version of the storage system support
function: X'16' or higher
XP24000/XP20000 disk array
Version of the storage system support
function: X'21' or higher
Open/MF Consistency Preservation Function for
Cnt Ac-S Z
XP24000/XP20000 disk array
Version of the storage system support
function: X'22' or higher
P9500 disk array
Version of the storage system support
function: X'31' or higher
List of Messages 157