Troubleshooting Dpvm Using The Cli; Dpvm Configuration Not Available - Cisco 9134 - MDS Multilayer Fabric Switch Troubleshooting Manual

Mds 9000 family
Hide thumbs Also See for 9134 - MDS Multilayer Fabric Switch:
Table of Contents

Advertisement

Chapter 11
Troubleshooting VSANs, Domains, and FSPF
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Select the Active Database tab.
Step 4
Select Pending from the Compare To drop-down menu. You see a dialog box listing any differences
Step 5
between the active DPVM database and the pending database.
Select the CFS tab and set Config Action to commit if there are any pending changes that you want to
Step 6
save. Click Apply Changes.
Step 7
Select the Actions tab and select activate from the Actions drop-down menu to activate the database.
Click Apply Changes.

Troubleshooting DPVM Using the CLI

To troubleshoot DPVM using the CLI, follow these steps:
Use the show dpvm command in EXEC mode to verify that CFS distribution is enabled for DPVM.
Step 1
Optionally, use the dpvm distribute command in config mode to enable CFS distribution if required.
Use the show dpvm status command in EXEC mode to verify that autolearning is disabled.
Step 2
Optionally, use the no dpvm auto-learn command in config mode if you need to disable autolearning
before activating the database.
Step 3
Use the show dpvm pending-diff command in EXEC mode to compare the active and pending
databases.
Optionally use the dpvm commit command in config mode to commit any pending entries to the config
database.
Use the dpvm activate command in config mode to activate the database.
Step 4

DPVM Configuration Not Available

Symptom
Table 11-3
DPVM Configuration Not Available
Symptom
Possible Cause
DPVM configuration
DPVM has not been enabled.
is not available on
Fabric Manager or
CLI.
OL-9285-05
DPVM configuration is not available on Fabric Manager or CLI.
Dynamic Port VSAN Membership Issues
Solution
DPVM must be enabled before it can be configured.
Choose Fabricxx > All VSANs > DPVM and check the
Status field in Fabric Manager or use the show dpvm
status CLI command to verify that DPVM is not enabled.
Set the Status field to enable in Fabric Manager and then
click Apply Changes or use the dpvm enable CLI
command to enable DPVM.
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
11-11