Common Problems with Port Interfaces
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Port Remains in Initializing State

Symptom
A port goes into the initialization state after a successful completion of link level initialization. For Fx
and FL types of ports, the next step is to complete the FLOGI process. The port remains in the
initialization state until the FLOGI (fabric login) process completes.
For E or TE port types, the next step is to complete the ELP process. If the ELP fails the port is moved
to the offline state after a timeout and the entire process repeats until the port comes online.
Table 8-4
Table 8-4
Port Remains in the Initializing State
Symptom
Possible Cause
Port remains in the
The port is up because the link partner
initializing state.
has put itself in a bypass mode.
The FLOGI packet was dropped
somewhere in the data path, starting
from FC-MAC to the FLOGI server.
A software bug resulted in an error
while handling the FLOGI packet.
We recommend that you do not disable and then enable a T or TE port. This would affect all the VSANs
Note
crossing the EISL instead of just the VSAN experiencing the problem.
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
8-16
Port remains in the initializing state.
lists possible causes for FLOGI to fail for a given port and possible solutions.
Solution
Use the show hardware internal fc-mac port port
statistics command to check whether the Class-3 input
counter is increasing after the successful completion of link
initialization.
You must use the attach module CLI command to
Note
access the FC-MAC show commands.
Use the show hardware internal fc-mac port port
statistics command to check for Class-3 packet counters.
You must use the attach module CLI command to
Note
access the FC-MAC show commands
Analyze the output of the show hardware internal error
command for a possible drop of FLOGI packets somewhere
in the path. See the
"NoteWe recommend that you do not
disable and then enable a T or TE port. This would affect
all the VSANs crossing the EISL instead of just the VSAN
experiencing the problem." section on page
Right-click on the port in Device Manager and select
disable and then enable, or use the shut CLI command
followed by the no shut command to disable and enable the
port. If this does not clear the problem, try moving the
connection to a different port on the same or another
module.
Chapter 8
Troubleshooting Ports
8-16.