Troubleshooting with Logs
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Viewing the Log from the Supervisor

You can view system messages from Device Manager if Device Manager is running from the same
workstation as the Fabric Manager Server. Choose Logs > Events > current to view the system
messages on Device Manager. The columns in the events table are sortable. In addition, you can use the
Find button to locate text within the table.
You can view switch-resident logs even if you have not set up your local syslog server or your local PC
is not in the switch's syslog server list. Because of memory constraints, these logs will wrap when they
reach a certain size. The switch syslog has two logs: an NVRAM log that holds a limited number of
critical and greater messages and a nonpersistent log that contains notice or greater severity messages.
Hardware messages are part of these logs.
Use the show logging CLI command to view the logs on the supervisor.

Viewing NVRAM logs

System messages that are priority 0, 1, or 2 are logged into NVRAM on the supervisor module. After a
switch reboots, you can display these syslog messages in NVRAM using the show logging nvram CLI
command. See
Example 1-2
switch# show logging nvram
2005 Sep 16 13:19:20 172.20.150.82 %PLATFORM-2-PS_OK: Power supply 2 ok (Serial
number )
2005 Sep 16 13:19:20 172.20.150.82 %PLATFORM-2-PS_FANOK: Fan in Power supply 2 ok
2005 Sep 16 13:19:20 172.20.150.82 %PLATFORM-2-FANMOD_FAN_OK: Fan module 1 (Front fan) ok
2005 Sep 16 13:19:20 172.20.150.82 %PLATFORM-2-FANMOD_FAN_OK: Fan module 2 (Rear fan) ok
2005 Sep 16 13:19:20 172.20.150.82 %PLATFORM-2-CHASSIS_CLKMODOK: Chassis clock module A ok
2005 Sep 16 13:19:20 172.20.150.82 %PLATFORM-2-CHASSIS_CLKMODOK: Chassis clock module B ok
2005 Sep 16 13:19:20 172.20.150.82 %PLATFORM-2-CHASSIS_CLKSRC: Current chassis clock
source is clock-A
2005 Sep 16 13:19:36 172.20.150.82 %PLATFORM-2-PFM_STDBY_BIOS_STUCK: standby supervisor
bios failed
2005 Sep 16 13:20:19 172.20.150.82 %IMAGE_DNLD-SLOT13-2-IMG_DNLD_STARTED:
download process. Please wait until completion...
2005 Sep 16 13:20:32 172.20.150.82 %IMAGE_DNLD-SLOT13-IMG_DNLD_COMPLETE:
download process. Download successful.
2005 Sep 16 15:44:46 172.20.150.82 %PLATFORM-2-PFM_STDBY_BIOS_STUCK: standby supervisor
bios failed
2005 Sep 16 15:44:53 172.20.150.82 %PLATFORM-2-MOD_ALL_PWRDN_NOXBAR: All modules powered
down due to non-availability of xbar modules
2005 Sep 16 15:45:41 172.20.150.82 %PLATFORM-2-MOD_PWRUP_XBAR: Modules powered up due to
xbar availability
2005 Sep 18 15:12:07 172.20.150.82 %MODULE-2-MOD_FAIL: Initialization of module 14
(serial: JAB092501FC) failed
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
1-14
Example
1-2.
Show logging nvram
Chapter 1
Troubleshooting Overview
Module image
Module image
OL-9285-05