Chapter 9
Troubleshooting N-Port Virtualization
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Check to ensure that the port mode on the NPV device side is set to "F-Port" and that the no shutdown
Step 2
command has been issued.

Waiting on FLOGI from the Server or Target

If you are waiting for the FLOGI from the server or target:
Enter the show npv status command to check the status of the link.
Step 1
switch# show npv status
npiv is enabled
Server Interfaces:
===================
Interface: fc1/6, VSAN: 1, NPIV: No, State: Waiting for FLOGI
Number of Server Interfaces: 7
If the State is "Waiting for FLOGI," then no FLOGI request was received from the server or target.
Step 2

Waiting on External Link to Come Up

If you are waiting for the external link to come up:
Enter the show npv status command to check the status of the link.
Step 1
switch# show npv status
npiv is enabled
Server Interfaces:
==================
Interface: fc1/6, VSAN: 1, NPIV: No, State: Waiting for External Interface
Number of Server Interfaces: 7
If the State is "Waiting for External Interface," check the status of external link. At least one external
Step 2
link must be up for server interface to be up.