Zone Merge Failure
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Do one of the following to resolve the isolation problem:
Step 3

Resolving Mismatched Active Zone Sets Within the Same VSAN Using the CLI

To verify a mismatched active zone set within the same VSAN using the CLI, follow these steps:
Step 1
Use the show zoneset active vsan-id command to display the active zone set configuration of the first
switch.
Switch1# show zoneset active vsan 99
zoneset name ZoneSet1 vsan 99
zone name VZ1 vsan 99
* fcid 0x7800e2 [pwwn 22:00:00:20:37:04:ea:2b]
* fcid 0x7800d9 [pwwn 22:00:00:20:37:04:f8:a1]
Step 2
Use the show zoneset active vsan-id command to display the active zone set configuration of the second
switch:
Switch2# show zoneset active vsan 99
zoneset name ZoneSet1 vsan 99
zone name VZ1 vsan 99
Even though the zones have the same name, their respective members are different.
Step 3
Issue the show interface command to view information about the TE port and the interface.
Switch2# show interface fc1/8
fc1/8 is trunking
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
14-18
Change the membership of one of the zones to match the other zone of the same name. See the
"Resolving Host and Storage Not in the Same Zone Using Fabric Manager" section on page
Discard one of the zone sets completely by deactivating it using the no zoneset activate command.
If a VSAN does not have an active zone set, it automatically takes the active zone set of the other
merging switch. See the
"Deactivating a Zone Set and Restarting the Zone Merge Process Using
Fabric Manager" section on page
Choose Zone > Copy Full Zone Database to overwrite the active zone set on one switch. This
method is destructive to one of the active zone sets.
pwwn 22:00:00:20:37:04:f8:a1
pwwn 22:00:00:20:37:0e:65:44
Hardware is Fibre Channel
Port WWN is 20:08:00:05:30:00:5f:1e
Peer port WWN is 20:05:00:05:30:00:86:9e
Admin port mode is E, trunk mode is auto
Port mode is TE
Port vsan is 1
Speed is 2 Gbps
Receive B2B Credit is 255
Receive data field size is 2112
Beacon is turned off
Trunk vsans (admin allowed and active) (1,99)
Trunk vsans (up)
Trunk vsans (isolated)
Trunk vsans (initializing)
5 minutes input rate 120 bits/sec, 15 bytes/sec, 0 frames/sec
5 minutes output rate 88 bits/sec, 11 bytes/sec, 0 frames/sec
10845 frames input, 620268 bytes, 0 discards
0 CRC,
0 unknown class
0 too long, 0 too short