FICON Overview
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 16-1
Default FICON Port Numbering in the Cisco MDS 9000 Family (continued)
Slot
Product
Number
Cisco MDS
Slot 1
9513 Director
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot 10
Slot 11
Slot 12
Slot 13
You can use the ficon slot assign port-numbers CLI command to use any excess ports by assigning
Note
numbers to the slots. Before you assign numbers to the slots however, we recommend that you review
the default port number assignments for Cisco MDS 9000 switches shown in
Only Fibre Channel, PortChannel, and FCIP ports are mapped to FICON port numbers. Other types of
Note
interfaces do not have corresponding port numbers.

Reserved FICON Port Numbering Scheme

A range of 250 port numbers are available for you to assign to all the ports on a switch.
that you can have more than 250 physical ports on a switch and the excess ports do not have port numbers
in the default numbering scheme. When you have more than 250 physical ports on your switch, you can
have ports without port number assigned if they are not in a FICON VSAN, or you can assign duplicate
port numbers if they are not used in the same FICON VSAN. For example, you can configure port
number 1 on interface fc1/1 in FICON VSAN 10 and fc10/1 in FICON VSAN 20.
A VSAN can have a maximum of 250 port numbers.
Note
FICON port numbers are not changed for ports that are active. You must first disable the interfaces using
Note
the shutdown CLI command.
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
16-4
Implemented Port Allocation
To Ports
To PortChannel/FCIP
0 through 15
224 through 249
16 through 31
32 through 47
48 through 63
64 through 79
80 through 95
None
None
96 through 111
112through 127
128 through 143
144 through 159
160 through 175
Chapter 16
Unimplemented
Ports
Notes
250 through 253
The first 4, 12 or 16 port
and port 255
numbers are used for a 4-port,
12-port or 16-port model, and
the rest remain unused.
Extra ports on 24-port, 32-port,
and 48-port modules are not
allocated port numbers.
Supervisor modules are not
allocated port numbers.
The first 4 or 12 port numbers
are used for a 4-port or 12-port
module, and the rest remain
unused. Extra ports on 24-port,
32-port, and 48-port modules
are not allocated port numbers.
Troubleshooting FICON
Table
16-1.
Table 16-1
shows
OL-9285-05

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading