Chapter 19
Troubleshooting FC-SP, Port Security, and Fabric Binding
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Verifying FC-SP Configuration Using Fabric Manager

To verify the FC-SP configuration using Fabric Manager, follow these steps:
Step 1
Choose Switches > Security > FC-SP and select the General/Password tab to view the configured
DHCHAP timeout value.
Step 2
Set the Timeout field to modify the timeout value.
Step 3
Set the DH-CHAP HashList field to modify the DHCHAP hash algorithm.
Set the DH-CHAP GroupList field to modify the DHCHAP group settings.
Step 4

Verifying FC-SP Configuration Using the CLI

To verify the FC-SP configuration using the CLI, follow these steps:
Use the show fcsp command to view the configured DHCHAP timeout value.
Step 1
switch# show fcsp
fc-sp authentication TOV:30
Use the fcsp timeout command to modify the timeout value.
Step 2
switch(config)# fcsp timeout 60
Use the show fcsp dhchap command to view the hash algorithm and group
Step 3
switch# show fcsp dhchap
Supported Hash algorithms (in order of preference):
DHCHAP_HASH_MD5
DHCHAP_HASH_SHA_1
Supported Diffie Hellman group ids (in order of preference):
DHCHAP_GROUP_1536
Use the fcsp dhchap hash command to modify the DHCHAP hash algorithm.
Step 4
switch(config)# fcsp dhchap hash MD5
Use the fcsp dhchap group command to modify the DHCHAP group settings.
Step 5
switch(config)# fcsp dhchap group 2 3 4

Verifying Local FC-SP Database Using Fabric Manager

To verify the local FC-SP database using Fabric Manager, follow these steps:
Choose Switches > Security > FC-SP and select the Local Passwords tab and the Remote Password
Step 1
tab to view the configured switches and hosts.
Choose Switches > FC Services > WWN Manager to find the sWWN for the switch.
Step 2
Choose Switches > Interfaces > FC Logical and select the FLOGI tab to find the pWWN for the host
Step 3
that you want to add to the FC-SP local database.