Figure 3-13 Console Port Settings - SMC Networks 6726AL2 Management Manual

Tigerswitch 10/100 24/48-port 10/100mbps fast ethernet managed switch
Hide thumbs Also See for 6726AL2:
Table of Contents

Advertisement

Speed – Sets the terminal line's baud rate for transmit (to terminal) and
receive (from terminal). Set the speed to match the baud rate of the
device connected to the serial port. (Range: 9600, 19200, 38400, 57600,
or 115200 baud; Default: 9600 bps)
Stop Bits – Sets the number of the stop bits transmitted per byte.
(Range: 1-2; Default: 1 stop bit)
Password
connection is started on a line with password protection, the system
prompts for the password. If you enter the correct password, the
system shows a prompt. (Default: No password)
Login
authentication by a single global password as configured for the
Password parameter, or by passwords set up for specific user-name
accounts. (Default: Local)
Web – Click System, Line, Console. Specify the console port connection
parameters as required, then click Apply.
3. CLI only.
3
– Specifies a password for the line connection. When a
– Enables password checking at login. You can select
3

Figure 3-13 Console Port Settings

B
C
ASIC
ONFIGURATION
3-29