Enabling Snmp Management Access; Community Strings - SMC Networks 6726AL2 Management Manual

Tigerswitch 10/100 24/48-port 10/100mbps fast ethernet managed switch
Hide thumbs Also See for 6726AL2:
Table of Contents

Advertisement

6. Then save your configuration changes by typing "copy running-config
startup-config." Enter the startup file name and press <Enter>.
Console(config)#interface vlan 1
Console(config-if)#ip address dhcp
Console(config-if)#end
Console#ip dhcp restart
Console#show ip interface
IP address and netmask: 192.168.1.54 255.255.255.0 on VLAN 1,
and address mode: User specified.
Console#copy running-config startup-config
Startup configuration file name []: startup
\Write to FLASH Programming.
\Write to FLASH finish.
Success.

Enabling SNMP Management Access

The switch can be configured to accept management commands from
Simple Network Management Protocol (SNMP) applications such as
SMC EliteView. You can configure the switch to (1) respond to SNMP
requests or (2) generate SNMP traps.
When SNMP management stations send requests to the switch (either to
return information or to set a parameter), the switch provides the
requested data or sets the specified parameter. The switch can also be
configured to send information to SNMP managers (without being
requested by the managers) through trap messages, which inform the
manager that certain events have occurred.

Community Strings

Community strings are used to control management access to SNMP
stations, as well as to authorize SNMP stations to receive trap messages
from the switch. You therefore need to assign community strings to
specified users or user groups, and set the access level.
B
C
ASIC
ONFIGURATION
2-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smc6726al2Smc6752al2

Table of Contents