SMC Networks 6726AL2 - annexe 1 Installation Manual

24-port 10/100 mbps fast ethernet managed switch
Table of Contents

Advertisement

Quick Links

TigerSwitch 10/100
24-Port 10/100 Mbps
Fast Ethernet Managed Switch
◆ 24 auto-MDI/MDI-X 10BASE-T/100BASE-TX ports
◆ 2 Gigabit RJ-45 ports shared with 2 SFP transceiver slots
◆ 8.8 Gbps of aggregate bandwidth
◆ Non-blocking switching architecture
◆ Spanning Tree Protocol and Rapid STP
◆ Up to four LACP or static 4-port trunks
◆ Layer 2/3/4 CoS support through four priority queues
◆ Full support for VLANs with GVRP
◆ IGMP multicast filtering and snooping
◆ Support for jumbo frames up to 9 KB
◆ Manageable via console, Web, SNMP, RMON

Installation Guide

SMC6726AL2

Advertisement

Table of Contents
loading

Summary of Contents for SMC Networks 6726AL2 - annexe 1

  • Page 1: Installation Guide

    TigerSwitch 10/100 24-Port 10/100 Mbps Fast Ethernet Managed Switch ◆ 24 auto-MDI/MDI-X 10BASE-T/100BASE-TX ports ◆ 2 Gigabit RJ-45 ports shared with 2 SFP transceiver slots ◆ 8.8 Gbps of aggregate bandwidth ◆ Non-blocking switching architecture ◆ Spanning Tree Protocol and Rapid STP ◆...
  • Page 3 TigerSwitch 10/100 Installation Guide From SMC’s Tiger line of feature-rich workgroup LAN solutions 38 Tesla Irvine, CA 92618 January 2005 Phone: (949) 679-8000 Pub. # 150000016300H...
  • Page 4 Irvine, CA 92618 All rights reserved. Printed in Taiwan Trademarks: SMC is a registered trademark; and EZ Switch, TigerStack and TigerSwitch are trademarks of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders.
  • Page 5 All SMC products carry a standard 90-day limited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term.
  • Page 6 RIGHTS, WHICH MAY VARY FROM STATE TO STATE. NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS. * SMC will provide warranty service for one year following discontinuance from the active SMC price list. Under the limited lifetime warranty, internal and external power supplies, fans, and cables are covered by a standard one-year warranty from date of purchase.
  • Page 7: Japan Vcci Class A

    OMPLIANCES FCC - Class A This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment.
  • Page 8: Ce Mark Declaration Of Conformance For Emi And Safety

    OMPLIANCES CE Mark Declaration of Conformance for EMI and Safety (EEC) SMC contact for these products in Europe is: SMC Networks Europe, Edificio Conata II, Calle Fructuós Gelabert 6-8, 2 08970 - Sant Joan Despí, Barcelona, Spain. This information technology equipment complies with the requirements of the Council...
  • Page 9 OMPLIANCES Safety Compliance Warning: Fiber Optic Port Safety When using a fiber optic port, never look at the transmit laser while CLASS I it is powered on. Also, never look directly at the fiber TX port and LASER DEVICE fiber cable ends when they are powered on. Avertissment: Ports pour fibres optiques - sécurité...
  • Page 10 OMPLIANCES Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following: Power Cord Set U.S.A. and Canada The cord set must be UL-approved and CSA certified. The minimum specifications for the flexible cord are: - No.
  • Page 11 OMPLIANCES France et Pérou uniquement: Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à...
  • Page 12: Warnings And Cautionary Messages

    OMPLIANCES Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden: Schweiz Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen einhalten. Europe Das Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestanforderung) sein und die Aufschrift <HAR> oder <BASEC> tragen. Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”). Warnings and Cautionary Messages Warning: This product does not contain any serviceable user parts.
  • Page 13: End Of Product Life Span

    OMPLIANCES Environmental Statement The manufacturer of this product endeavours to sustain an environmentally-friendly policy throughout the entire production process. This is achieved though the following means: • Adherence to national legislation and regulations on environmental production standards. • Conservation of operational resources. •...
  • Page 14 OMPLIANCES...
  • Page 15: Table Of Contents

    ABLE OF ONTENTS About the TigerSwitch 10/100 ....1-1 Overview ..........1-1 Switch Architecture .
  • Page 16 ABLE OF ONTENTS Connecting to a Power Source ....... . 3-9 Connecting to the Console Port .
  • Page 17 ABLE OF ONTENTS PPENDICES Troubleshooting ......A-1 Diagnosing Switch Indicators ....... . . A-1 Power and Cooling Problems .
  • Page 18 ABLES Table 1-1 Port Status LEDs ....... . . 1-4 Table 1-2 System Status LEDs .
  • Page 19 IGURES Figure 1-1 Front and Rear Panels ......1-2 Figure 1-2 Port LEDs ........1-4 Figure 1-3 System LEDs .
  • Page 20 IGURES...
  • Page 21: About The Tigerswitch 10/100

    HAPTER BOUT THE 10/100 IGER WITCH Overview The SMC6726AL2 is a Fast Ethernet switch with 24 10BASE-T/ 100BASE-TX ports and two 1000BASE-T ports that operate in combination with two Small Form Factor Pluggable (SFP) transceiver slots (see Figure 1-1, Ports 25-26). The switch also includes an SNMP-based management agent, which provides both in-band and out-of-band access for managing the switch.
  • Page 22: Switch Architecture

    10/100 BOUT THE IGER WITCH System Indicators Port Status Indicators Diag 10/100 Mbps RJ-45 Ports 1000BASE-T/SFP Ports 100-240V~ 50-60Hz 0.8A Console Port Power Socket Figure 1-1 Front and Rear Panels Switch Architecture The SMC6726AL2 switch employs a wire-speed, non-blocking switching fabric.
  • Page 23: Description Of Hardware

    ESCRIPTION OF ARDWARE Description of Hardware RJ-45 Ports The SMC6726AL2 contains 24 10/100BASE-TX RJ-45 ports and two 10/ 100/1000BASE-T RJ-45 ports that are shared with two SFP slots. All of the RJ-45 ports can operate at 10 Mbps or 100 Mbps, half or full duplex. The Gigabit ports can also operate at 1000 Mbps, full duplex.
  • Page 24: Table 1-1 Port Status Leds

    10/100 BOUT THE IGER WITCH Port Status LEDs Figure 1-2 Port LEDs Table 1-1 Port Status LEDs Condition Status Fast Ethernet Ports (Ports 1-24) (Link/ On/Flashing Port has established a valid 10 Mbps network Activity) Amber connection. Flashing indicates activity. On/Flashing Port has established a valid 100 Mbps network Green...
  • Page 25: Table 1-2 System Status Leds

    ESCRIPTION OF ARDWARE System LEDs Diag Figure 1-3 System LEDs Table 1-2 System Status LEDs Condition Status On Green The unit’s internal power supply is operating normally. On Amber The unit’s internal power supply has failed. The unit has no power connected or has failed.
  • Page 26: Power Supply Receptacle

    10/100 BOUT THE IGER WITCH Power Supply Receptacle The power receptacle is located on the rear panel of the switch. The standard power receptacle is for the AC power cord. 100-240V~ 50-60Hz 0.8A Figure 1-4 Power Supply Receptacle Features and Benefits Connectivity •...
  • Page 27: Expandability

    EATURES AND ENEFITS • IEEE 802.3-2002 Ethernet, Fast Ethernet, Gigabit Ethernet compliance ensures compatibility with standards-based hubs, network cards and switches from any vendor. Expandability • 2 Small Form Factor Pluggable (SFP) transceiver slots (shared with 1000BASE-T ports). • Supports 1000BASE-SX, 1000BASE-LX, 1000BASE-ZX and other SFP-compatible transceivers.
  • Page 28 10/100 BOUT THE IGER WITCH...
  • Page 29: Network Planning

    HAPTER ETWORK LANNING Introduction to Switching A network switch allows simultaneous transmission of multiple packets via non-crossbar switching. This means that it can partition a network more efficiently than bridges or routers. The switch has, therefore, been recognized as one of the most important building blocks for today’s networking technology.
  • Page 30: Application Examples

    ETWORK LANNING Application Examples The SMC6726AL2 switch is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. Some typical applications are described below. Collapsed Backbone The SMC6726AL2 switch is an excellent choice for Ethernet, Fast Ethernet, and Gigabit Ethernet installations where significant growth is expected in the near future.
  • Page 31: Network Aggregation Plan

    PPLICATION XAMPLES Network Aggregation Plan With 26 parallel bridging ports (i.e., 26 distinct collision domains), the SMC6752AL2 switch can collapse a complex network down into a single efficient bridged node, increasing overall bandwidth and throughput. In the figure below, the 10BASE-T/100BASE-TX ports are providing 100 Mbps connectivity for up to 24 segments.
  • Page 32: Remote Connections With Fiber Cable

    ETWORK LANNING Remote Connections with Fiber Cable Fiber optic technology allows for longer cabling than any other media type. A 1000BASE-SX (MMF) link can connect to a site up to 550 meters away, a 1000BASE-LX (SMF) link up to 5 km, and a 1000BASE-ZX link up to 100 km.
  • Page 33: Making Vlan Connections

    PPLICATION XAMPLES Making VLAN Connections This switch supports VLANs which can be used to organize any group of network nodes into separate broadcast domains. VLANs confine broadcast traffic to the originating group, and can eliminate broadcast storms in large networks. This provides a more secure and cleaner network environment.
  • Page 34: Application Notes

    ETWORK LANNING Application Notes 1. Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. 2.
  • Page 35: Installing The Switch

    HAPTER NSTALLING THE WITCH Selecting a Site Switch units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location. • The site should: be at the center of all the devices you want to link and near a power outlet.
  • Page 36: Ethernet Cabling

    NSTALLING THE WITCH Ethernet Cabling To ensure proper operation when installing the switch into a network, make sure that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T operation. Check the following criteria against the current installation of your network: •...
  • Page 37: Equipment Checklist

    • This Installation Guide • Management Guide • SMC Warranty Registration Card—be sure to complete and return to Optional Rack-Mounting Equipment If you plan to rack-mount the switch, be sure to have the following equipment available: • Four mounting screws for each device you plan to install in a rack—these are not included...
  • Page 38: Mounting

    NSTALLING THE WITCH Mounting This switch can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Rack Mounting Before rack mounting the switch, pay particular attention to the following factors: •...
  • Page 39: Figure 3-2 Attaching The Brackets

    OUNTING To rack-mount devices: 1. Attach the brackets to the device using the screws provided in the Bracket Mounting Kit. Figure 3-2 Attaching the Brackets 2. Mount the device in the rack, using four rack-mounting screws (not provided). Figure 3-3 Installing the Switch in a Rack...
  • Page 40 NSTALLING THE WITCH 3. If installing a single switch only, turn to “Connecting to a Power Source” at the end of this chapter. 4. If installing multiple switches, mount them in the rack, one below the other, in any order. Montage (Rack Mounting Instructions - German) ES3526XA Switch-Einheiten können an ein standardmäßiges 19-Zoll Einrichtungsrack, einen Arbeitstisch oder ein Regal montiert werden.
  • Page 41: Desktop Or Shelf Mounting

    OUNTING Desktop or Shelf Mounting 1. Attach the four adhesive feet to the bottom of the first switch. Figure 3-4 Attaching the Adhesive Feet 2. Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper air flow. 3.
  • Page 42: Installing An Optional Sfp Transceiver

    NSTALLING THE WITCH Installing an Optional SFP Transceiver P W R D ia g Figure 3-5 Installing an SFP Transceiver into a Slot This switch supports 1000BASE-SX, 1000BASE-LX, and 1000BASE-ZX SFP transceivers. To install an SFP transceiver, do the following: 1.
  • Page 43: Connecting To A Power Source

    ONNECTING TO A OWER OURCE Connecting to a Power Source To connect a switch to a power source: 1. Insert the power cable plug directly into the AC receptacle located at the back of the switch. 100-240V~ 50-60Hz 0.8A Figure 3-6 Power Receptacle 2.
  • Page 44: Connecting To The Console Port

    NSTALLING THE WITCH Connecting to the Console Port The DB-9 serial port on the switch’s rear panel is used to connect to the switch for out-of-band console configuration. The command-line-driven configuration program can be accessed from a terminal or a PC running a terminal emulation program.
  • Page 45: Making Network Connections

    HAPTER AKING ETWORK ONNECTIONS Connecting Network Devices The SMC6752AL2 switch is designed to interconnect multiple segments (or collision domains). It can be connected to network cards in PCs and servers, as well as to hubs, switches or routers. It may also be connected to remote devices using the optional 1000BASE-SX, 1000BASE-LX, or 1000BASE-ZX SFP transceivers.
  • Page 46: Connecting To Pcs, Servers, Hubs And Switches

    AKING ETWORK ONNECTIONS Caution: Do not plug a phone jack connector into an RJ-45 port. This will damage the switch. Use only twisted-pair cables with RJ-45 connectors that conform to FCC standards. Connecting to PCs, Servers, Hubs and Switches 1. Attach one end of a twisted-pair cable segment to the device’s RJ-45 connector.
  • Page 47: Network Wiring Connections

    WISTED EVICES 3. As each connection is made, the Link LED (on the switch) corresponding to each port will light to indicate that the connection is valid. Network Wiring Connections Today, the punch-down block is an integral part of many of the newer equipment racks.
  • Page 48: Fiber Optic Sfp Devices

    AKING ETWORK ONNECTIONS Fiber Optic SFP Devices An optional Gigabit SFP transceiver (1000BASE-SX, 1000BASE-LX, or 1000BASE-ZX) can be used for a backbone connection between switches, or for connecting to a high-speed server. Each single-mode fiber port requires 9/125 micron single-mode fiber optic cable with an LC connector at both ends.
  • Page 49: Figure 4-3 Making Fiber Port Connections

    SFP D IBER PTIC EVICES 3. Connect one end of the cable to the LC port on the switch and the other end to the LC port on the other device. Since LC connectors are keyed, the cable can be attached in only one orientation. P W R D ia g Figure 4-3 Making Fiber Port Connections...
  • Page 50: Connectivity Rules

    AKING ETWORK ONNECTIONS Connectivity Rules When adding hubs (repeaters) to your network, please follow the connectivity rules listed in the manuals for these products. However, note that because switches break up the path for connected devices into separate collision domains, you should not include the switch or connected cabling in your calculations for cascade length involving other devices.
  • Page 51: 100 Mbps Fast Ethernet Collision Domain

    ONNECTIVITY ULES Table 4-2 Maximum 1000BASE-SX Gigabit Ethernet Cable Lengths 50/125 micron 400 MHz/km 2-500 m (7-1641 ft) multimode fiber 500 MHz/km 2-550 m (7-1805 ft) Table 4-3 Maximum 1000BASE-LX Gigabit Ethernet Cable Length Fiber Size Fiber Maximum Cable Connector Bandwidth Length 9/125 micron...
  • Page 52: Cable Labeling And Connection Records

    AKING ETWORK ONNECTIONS Cable Labeling and Connection Records When planning a network installation, it is essential to label the opposing ends of cables and to record where each cable is connected. Doing so will enable you to easily locate inter-connected devices, isolate faults and change your topology without need for unnecessary time consumption.
  • Page 53: Diagnosing Switch Indicators

    PPENDIX ROUBLESHOOTING Diagnosing Switch Indicators Table A-1 Troubleshooting Chart Symptom Action PWR LED is Off • Check connections between the switch, the power cord and the wall outlet. • Contact your dealer for assistance. PWR LED is Amber • Internal power supply has failed. Contact your local dealer for assistance.
  • Page 54: Installation

    ROUBLESHOOTING Installation Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly. In-Band Access You can access the management agent in the switch from anywhere within the attached network using Telnet, a web browser, or other network...
  • Page 55: Cables

    PPENDIX ABLES Twisted-Pair Cable and Pin Assignments For 10/100BASE-TX connections, the twisted-pair cable must have two pairs of wires. For 1000BASE-T connections the twisted-pair cable must have four pairs of wires. Each wire pair is identified by two different colors. For example, one wire might be green and the other, green with white stripes.
  • Page 56: 10Base-T/100Base-Tx Pin Assignments

    ABLES 10BASE-T/100BASE-TX Pin Assignments Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Category 3 or better cable for 10 Mbps connections, or 100-ohm Category 5 or better cable for 100 Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
  • Page 57: Straight-Through Wiring

    WISTED ABLE AND SSIGNMENTS Straight-Through Wiring If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs of wires must be straight-through. (When auto-negotiation is enabled for any RJ-45 port on this switch, you can use either straight-through or crossover cable to connect to any device type.) You must connect all four wire pairs as shown in the following diagram to...
  • Page 58: 1000Base-T Pin Assignments

    ABLES EIA/TIA 568B RJ-45 Wiring Standard 10/100BASE-TX Crossover Cable White/Orange Stripe Orange White/Green Stripe End A End B Blue White/Blue Stripe Green White/Brown Stripe Brown Figure B-3 Crossover Wiring 1000BASE-T Pin Assignments All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
  • Page 59: 1000Base-T Cable Requirements

    WISTED ABLE AND SSIGNMENTS Table B-2 1000BASE-T MDI and MDI-X Port Pinouts MDI Signal Name MDI-X Signal Name Bi-directional Data One Plus (BI_D1+) Bi-directional Data Two Plus (BI_D2+) Bi-directional Data One Minus (BI_D1-) Bi-directional Data Two Minus (BI_D2-) Bi-directional Data Two Plus (BI_D2+) Bi-directional Data One Plus (BI_D1+) Bi-directional Data Three Plus (BI_D3+) Bi-directional Data Four Plus (BI_D4+)
  • Page 60: Fiber Standards

    ABLES Note that when testing your cable installation, be sure to include all patch cables between switches and end devices. Adjusting Existing Category 5 Cabling to Run 1000BASE-T If your existing Category 5 installation does not meet one of the test parameters for 1000BASE-T, there are basically three measures that can be applied to try and correct the problem: 1.
  • Page 61: Specifications

    PPENDIX PECIFICATIONS Physical Characteristics Ports 24 10BASE-T/100BASE-TX, with auto-negotiation 2 1000BASE-T shared with two SFP transceiver slots Network Interface Ports 1-26: RJ-45 connector, auto MDI/X 10BASE-T: RJ-45 (100-ohm, UTP cable; Category 3 or better) 100BASE-TX: RJ-45 (100-ohm, UTP cable; Category 5 or better) 1000BASE-T: RJ-45 (100-ohm, UTP or STP cable;...
  • Page 62: Switch Features

    PECIFICATIONS Humidity Operating: 10% to 90% (non-condensing) AC Input 100 to 240 V, 50-60 Hz, 0.8A Power Supply Internal, auto-ranging transformer: 100 to 240 VAC, 50 to 60 Hz Power Consumption 25 Watts maximum Maximum Current 0.6 A @ 100 VAC 0.3 A @ 240 VAC Switch Features Forwarding Mode...
  • Page 63: Standards

    TANDARDS Software Loading TFTP in-band, or XModem out-of-band Standards IEEE 802.3-2002 Ethernet Fast Ethernet Gigabit Ethernet Full-duplex flow control IEEE 802.1D (STP) IEEE 802.1w (RSTP) ISO/IEC 8802-3 Compliances CE Mark Emissions FCC Class A Industry Canada Class A EN55022 (CISPR 22) Class A EN 61000-3-2/3 VCCI Class A Immunity...
  • Page 64 PECIFICATIONS...
  • Page 65: Table D-1 Tigerswitch 10/100 Products And Accessories

    PPENDIX RDERING NFORMATION Table D-1 TigerSwitch 10/100 Products and Accessories Product Number Description SMC6726AL2 24 100BASE-TX port switch with four 1000BASE-T ports, two of which are shared with SFP transceiver slots SMCBGSLCX1 1-port 1000BASE-SX Small Form Pluggable (SFP) transceiver SMCBGLLCX1 1-port 1000BASE-LX Small Form Pluggable (SFP) transceiver SMCBGZLCX1...
  • Page 66: Ordering Information

    RDERING NFORMATION...
  • Page 67: Glossary

    LOSSARY 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or 5 UTP cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps Ethernet over two pairs of Category 5 UTP cable. 1000BASE-LX IEEE 802.3z specification for Gigabit Ethernet over two strands of 50/ 125, 62.5/125 or 9/125 micron core fiber cable.
  • Page 68 LOSSARY Bandwidth The difference between the highest and lowest frequencies available for network signals. Also synonymous with wire speed, the actual speed of the data transmission along the cable. Collision A condition in which packets transmitted over the cable interfere with each other.
  • Page 69 LOSSARY Full Duplex Transmission method that allows two network devices to transmit and receive concurrently, effectively doubling the bandwidth of that link. Gigabit Ethernet A 1000 Mbps network communication system based on Ethernet and the CSMA/CD access method. IEEE Institute of Electrical and Electronic Engineers. IEEE 802.3 Defines carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications.
  • Page 70: Network Diameter

    LOSSARY Light emitting diode used for monitoring a device or network condition. Local Area Network (LAN) A group of interconnected computer and support devices. Media Access Control (MAC) A portion of the networking protocol that governs access to the transmission medium, facilitating the exchange of data between network nodes.
  • Page 71 LOSSARY Telecommunications Industry Association Transmission Control Protocol/Internet Protocol (TCP/IP) Protocol suite that includes TCP as the primary transport protocol, and IP as the network layer protocol. Unshielded twisted-pair cable. Virtual LAN (VLAN) A Virtual LAN is a collection of network nodes that share the same collision domain regardless of their physical location or connection point in the network.
  • Page 72 LOSSARY Glossary-6...
  • Page 73: Index

    NDEX Numerics safety C-3 connectivity rules 10 Mbps connectivity rules 4-7 10 Mbps 4-7 100 Mbps connectivity rules 4-7 100 Mbps 4-7 1000 Mbps connectivity rules 4-6 1000 Mbps 4-6 1000BASE-LX fiber cable lengths 4-7 console port 1000BASE-SX fiber cable lengths 4-6 pin assignments 3-10 1000BASE-ZX fiber cable lengths 4-7 contents of package 3-3...
  • Page 74 NDEX IEEE 802.3x flow control 1-3 ordering information D-1 indicators, LED 1-3 out-of-band management 1-2 installation connecting devices to the switch 4-2 desktop or shelf mounting 3-7 network wiring connections 4-3 package contents 3-3 port connections 4-1 pin assignments B-1 power requirements 3-1 1000BASE-T B-4 problems A-2...
  • Page 75 NDEX IEEE C-3 troubleshooting status LEDs 1-3 in-band access A-2 switch architecture 1-2 power and cooling problems A-1 switching switch indicators A-1 introduction to 2-1 twisted-pair connections 4-1 method 1-2 VLANs, tagging 2-5 Telnet A-2 temperature within a rack 3-4 TigerSwitch 10/100 Products and Accessories D-1 Web-based management 1-2...
  • Page 76 NDEX Index-4...
  • Page 78 97 14 299 4466 Fax 97 14 299 4664 Thailand: 66 2 651 8733 Fax 66 2 651 8737 If you are looking for further contact information, please visit www.smc.com, www.smc-europe.com, or www.smc-asia.com. 38 Tesla Model Number: SMC6726AL2 Irvine, CA 92618 Pub.

This manual is also suitable for:

Tigerswitch smc6726al2

Table of Contents