Adjust Controlled Zones

IMPORTANT: Moving a populated zone may cause communication errors. If possible, move zones before devices are
assigned. Refer to "Resolve Mobile Application Communication Issues" on page 164 if communication errors occur.
To adjust the controlled zones:
1: Bring the mobile device within range (within 60 feet) of any line voltage powered provisioned WaveLinx Lite device in the desired area.
2: Ensure that the mobile device Bluetooth is turned on, and then open the WaveLinx Lite Mobile Application.
3: In the site list, select a site.
4: In the area list, select the desired area. After a short delay, verify that the area shows that the mobile application is connected to the network.
Tap on the
icon if it is necessary to refresh the connection.
5: Tap on 'occupancy' to open the occupancy set list.
6. Next, tap on the occupancy set containing the control zone to be removed.
72
If occupancy is sensed in the 30 seconds after an unoccupied command is issued (grace period), the device will resume the previous light level. If outside of the grace
period, the light level issued when occupied will be as defined for the occupied command. Devices with older firmware may not observe the 30 second grace period.
92
www.cooperlighting.com
Setting
Default
Occupied State
Level 100%
Energy State
Level 50%
Unoccupied
Level 0%
State
Description
Tap ' ' in the 'Occupied State' section to expand and show the
zone(s) programmed occupied level(s). This is the light level
that will be issued when motion is initially detected.
'Occupied State' will not show if vacancy mode is selected.
Tap ' ' next to the zone to adjust the occupied light level
using the slider bar, raise lower controls, or text box entry.
Dimmable zones will respond to the level defined. For non-
dimmable or receptacle zones 0% = OFF, 1% to 100%= ON. Tap
'Save' if changes are made.
Tap ' ' in the 'Energy State' section to expand and show the
zone(s) programmed energy state level(s). If Energy Saver
Mode is enabled, this setting defines the light level that will be
issued to dimmable zones once the area is unoccupied and the
Energy Saver Mode time expires. Non dimmable zones will
remain at their occupied state.
Tap ' ' next to the zone to adjust each dimmable zone to
adjust the energy saver light level using the slider bar, raise
lower controls, or text box entry. Dimmable zones will respond
to the level defined. Tap 'Save' if changes are made.
Tap ' ' in the 'Unoccupied State' section to expand and show
the zone(s) programmed unoccupied level(s). This is the light
level that will be issued when the hold time expires.
Tap ' ' next to the zone to adjust the unoccupied light level
using the slider bar, raise lower controls, or text box entry.
Dimmable zones will respond to the level defined. For non-
dimmable or receptacle zones 0% = OFF, 1% to 100%= ON. Tap
'Save' if changes are made.