Download Print this page

Cooper Metalux CGTS NUV Installation Instructions Manual

Surface mount
Hide thumbs Also See for Metalux CGTS NUV:

Advertisement

Available languages

Available languages

Quick Links

IB519158EN
CGTS NUV Surface Mount installation Instructions
Directives d'installation de montage en surface CGTS NUV
Instrucciones de instalación del montaje en superficie para
CGTS NUV
IMPORTANT: Read carefully before installing fixture. Failure to comply with these instructions may result in death,
serious bodily injury and property damage. Retain for future reference.
Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product
must be performed by a qualified electrician. This product must be installed in accordance with the
applicable installation code by a person familiar with the construction and operation of the product and
hazards involved. The light source contained in this luminaire shall only be replaced by the manufacturer or
his service agent or a similar qualified person.
Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any
maintenance. Disconnect power at fuse or circuit breaker.
Risk of Fire- Minimum 90°C supply conductors.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may
arise from the improper, careless, or negligent installation, handling or use of this product.
NOTICE: Ground screw provided in proper location. Do not relocate.
NOTICE: Fixture may become damaged and/or unstable if not installed properly.
Note: Specifications and dimensions subject to change without notice.
ATTENTION Receiving Department: Note actual fixture description of any shortage or noticeable damage on delivery
receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be filed within 15
days of delivery. All damaged material, complete with original packing must be retained.
Connect fixture to a 120/277V/347V, 60Hz power supply. Any other connection voids the warranty.
N
ote:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
N
ote:
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved
N
ote:
by the manufacturer could void the user's authorization to operate this equipment.
WARNING
Metalux

Advertisement

loading

Summary of Contents for Cooper Metalux CGTS NUV

  • Page 1 Risk of Personal Injury- Due to sharp edges, handle with care. DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product.
  • Page 2: Installation Instructions

    CGTS NUV Surface Mount Instructions Installation Instructions Surface Mount Kits suited for 2x2ft panel Dimensional Drawing 609.8 4-Ø4.5 70.0 Surface mounting frame for LED panel lights(fully assembled already) 30mm self-tapping screws x 4pcs Baffle Plate-A 6mm plastic Baffle Plate-B Unit:mm X 2PCS(RAL9003) capsules x 4pcs X 2PCS(RAL9003)
  • Page 3 CGTS NUV Surface Mount Instructions Installation Instructions It is the installer’s responsibility to create the ote: required electrical supply prior to installing the mounting frames. Remove end piece ote: The 2x2 Installation Diagram. The 1x4, 2x4 and 2x2 installation method are the same. Masonary mounting Ceiling Wall plugs...
  • Page 4 Risk of Personal Injury- à cause des arêtes tranchantes, manipulez ce produit avec précaution. EXONÉRATION DE RESPONSABILITÉ : Cooper Lighting Solutions n’assume aucune responsabilité pour les dommages ou pertes de quelque nature que ce soit pouvant découler d’une installation, d’une manipulation ou d’une utilisation inappropriée, imprudente ou négligente de ce produit.
  • Page 5: Instructions D'installation

    Directives d’installation de montage en surface CGTS NUV Instructions d’installation Trousse de montage en surface pour les panneaux de 60 x 60 cm (2 x 2 pi) Plan dimensionnel 609.8 4-Ø4.5 70.0 Cadre de montage en surface pour DEL Panneaux d’éclairage (entièrement assemblés) 4 vis autotaraudeuses 30 mm Déflecteur A plastique 6 mm...
  • Page 6 Directives d’installation de montage en surface CGTS NUV Instructions d’installation Il incombe à l’installateur de créer l’alimentation ote: électrique requise avant d’installer les cadres de montage. Retirez l’embout ote: Indiqué dans le schéma d’installation des panneaux de 60 x 60 cm (2 x 2 pi). La méthode d’installation Montage sur un mur en pour les panneaux de 30 x 120 cm (1 x 4 pi), de maçonnerie...
  • Page 7 Riesgo de lesiones personales: debido a los bordes afilados, manejar con cuidado. EXENCIÓN DE RESPONSABILIDAD: Cooper Lighting Solutions no asume ninguna responsabilidad por daños o pérdidas de ningún tipo que puedan surgir de la instalación, el manejo o el uso incorrectos, descuidados o negligentes de este producto.
  • Page 8: Instrucciones De Instalación

    Instrucciones de instalación del montaje en superficie para CGTS NUV Instrucciones de instalación Kits de montaje en superficie adecuados para paneles de 2 x 2 ft (60,96 x 60,96 cm) Plano dimensional 609.8 4-Ø4.5 70.0 Marco de montaje en superficie para luces del panel LED (ya completamente ensambladas) Tornillos autorroscantes de 30 mm x 4 piezas Placa deflectora A...
  • Page 9 Instrucciones de instalación del montaje en superficie para CGTS NUV Instrucciones de instalación Es responsabilidad del instalador crear el ote: suministro eléctrico necesario antes de instalar los marcos de montaje. Retire la pieza ote: Se muestra el diagrama de instalación de 2 x 2. El terminal método de instalación de 1 x 4, 2 x 4 y 2 x 2 es el Montaje de...
  • Page 10 Peachtree City, GA 30269 All trademarks are property P: 770-486-4800 of their respective owners. www.cooperlighting.com Cooper Lighting Solutions est une marque Product availability, specifications, Canada Sales de commerce déposée. and compliances are subject to 5925 McLaughlin Road Toutes les autres marques de commerce change without notice Mississauga, Ontario L5R 1B8...