Powering Off the M7i Router

126
Press the power switch for one power supply to the
5.
DC power supplies, the switch is located on the power supply faceplate.
Verify that the
6.
OUTPUT OK
NOTE:
After powering off a power supply, wait at least 60 seconds before
turning it back on. After powering on a power supply, wait at least 60
seconds before turning it off.
If the router is completely powered off when you power on the power
supply, the Routing Engine boots as the power supply completes its startup
sequence. If the Routing Engine finishes booting and you need to power
off the router again, see
After a power supply is powered on, it can take up to 60 seconds for status
indicators—such as the output status LED on the power supply, the
command display output, and messages on the LED display on the craft
interface—to indicate that the power supply is functioning normally. Ignore
error indicators that appear during the first 60 seconds.
Press the power switch for the second power supply to the
7.
that the
OUTPUT OK
LED lights steadily. If the LED does not light after 60 seconds,
verify that the power supply is properly inserted into the chassis and repeat the cable
installation procedures described in
on page 123
or
"Connecting Power to a DC-Powered Router" on page
On the external management device connected to the Routing Engine, monitor the
8.
startup process to verify that the system has booted properly.
Troubleshooting the M7i Power System When the LED on One M7i Power Supply Is Off
on page 206
Troubleshooting the M7i Power System When the LEDs on All M7i Power Supplies Are
Blinking or Off on page 206
General Electrical Safety Guidelines and Electrical Codes for M Series, MX Series, and
T Series Routers on page 254
To power off the router:
On the console or other management device connected to the master Routing Engine,
1.
enter CLI operational mode and issue the following command to shut down the router
software. (If two Routing Engines are installed, also issue the command on the backup
Routing Engine.)
ON
LED lights steadily.
"Powering Off the M7i Router" on page
"Connecting Power to an AC-Powered M7i Router"
Copyright © 2019, Juniper Networks, Inc.
(
) position. On both AC and
|
126.
(
) position and verify
ON
|
124.

Advertisement

Table of Contents
loading

Table of Contents