3.3.3 User-defined DI and DO signals

If the default DI and DO signals could not be able to fulfill the users' requirements, there are still user-
defined DI and DO signals. The setting method is easy and they are all defined via parameters. The
user-defined DI and DO signals are defined via parameters P2-10 to P2-15 and P2-18 to P2-20.
Please refer to the following Table 3.G for the settings.
Table 3.G User-defined DI and DO signals
Signal Name
DI1-
DI2-
DI3-
DI
DI4-
DI5-
DI6-
DI signal:
For example: If the users want to set DI1 to be servo on, it only needs to set the value of parameter P2-
10 to 101 (refer to chapter 7).
NOTE
1) 14~17: Single control mode;18~20: Dual control mode; 0: Input function disabled
DI Code
01
02
03
04
05
06
07
09
10
11
14
15
16
17
18
3-18
Default Pin
Parameter
No.
17
P2-10
18
P2-11
5
P2-12
3
P2-13
15
P2-14
14
P2-15
Setting of parameter P2-10 to P2-15:
Signal
SON
Servo On
ARST
Alarm Reset
GAINUP
Gain switching in speed and position mode
CCLR
Pulse clear
ZCLAMP
Zero speed CLAMP
CMDINV
Command input reverse control
INHP
Pulse inhibit input
TRQLM
Torque limit enabled
SPDLM
Speed limit enabled
GNUM0
Electronic gear ratio (Numerator) selection 0
SPD0
Speed command selection 0
SPD1
Speed command selection 1
TCM0
Torque command selection 0
TCM1
Torque command selection 1
S-P
Position / Speed mode switching (OFF: Speed, ON: Position)
Default Pin
Signal Name
No.
DO1+
16
DO
DO2+
DO3+
Description
Parameter
P2-18
2
P2-19
1
P2-20
Revision January 2009