Analog Speed Input Drift Adjustment 1; Analog Speed Input Drift Adjustment 2; Analog Torque Drift Adjustment 1 - Delta Electronics ASDA-B Series User Manual

Asda-b series standard ac servo drive for general purpose applications
Table of Contents

Advertisement

P4 - 11
SOF1

Analog Speed Input Drift Adjustment 1

Default: Factory setting
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 32767
Settings:
Manual Adjustment Operation:
Set parameter P2-08 to 22 and then change this parameter. This is an auxiliary adjusting
function, although this parameter allows the users can execute manual adjustment, we still do
not recommend users to change the default setting manually.
Auto Adjustment Operation:
Set parameter P2-08 to 20 first and then set parameter P4-10 to 1.
When executing this auto adjustment, ensure that the external wiring connected to analog speed
must be removed or an external zero voltage power is applied to the servo drive from the host
controller and the servo system should be off (Servo off).
NOTE
1) When P2-08 is set to 10, users cannot reset this parameter.
P4 - 12
SOF2

Analog Speed Input Drift Adjustment 2

Default: Factory setting
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 32767
Settings:
Please see P4-11 for explanation.
NOTE
1) When P2-08 is set to 10, users cannot reset this parameter.
P4 - 13
TOF1

Analog Torque Drift Adjustment 1

Default: Factory setting
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 32767
Settings:
Manual Adjustment Operation:
Set parameter P2-08 to 22 and then change this parameter. This is an auxiliary adjusting
Revision January, 2009
Chapter 7 Servo Parameters|ASDA-B Series
Communication Addr.: 040BH
Related Section:
P4-10
Communication Addr.: 040CH
Related Section:
P4-10
Communication Addr.: 040DH
Related Section:
P4-10
7-63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents