Delta Electronics ASDA-B Series User Manual page 84

Asda-b series standard ac servo drive for general purpose applications
Table of Contents

Advertisement

Monitor Setting Display
In monitor mode, in order to change the monitor status, the users can press UP or DOWN arrow key or
change parameter P0-02 directly to specify the monitor status. When the power is applied, the monitor
status depends on the setting value of P0-02. For example, if the setting value of P0-02 is 2 when the
power is applied, the monitor function will be "Pulse counts of pulse command", the C.P monitor codes
will first display and then the pulse number will display after.
P0-02
Setting
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Revision January 2009
Display Message
Chapter 4 Display and Operation|ASDA-B Series
Description
Motor feedback pulse number
Motor feedback rotation number
Pulse counts of pulse command
Rotation number of pulse command
Position error counts
Input frequency of pulse command
Motor rotation speed
Speed input command
Speed input command
Torque input command
Torque input command
Average load
Peak load
Main circuit voltage
Unit
pulse
rev
pulse
rev
pulse
kHz
rpm
volt
rpm
volt
Nt-m
%
%
volt
4-29