Keypad Fault Messages - Delta Electronics ASDA-B Series User Manual

Asda-b series standard ac servo drive for general purpose applications
Table of Contents

Advertisement

Chapter 10 Troubleshooting|ASDA-B Series
Display
Input power phase loss One phase of the input power is loss.
ALE 20/ALE

Keypad Fault Messages

Display
ALE 30
LCM hardware error
ALE 31
LED hardware error
ALE 32
KEY hardware error
ALE 33
RAM hardware error
EEPROM hardware
ALE 34
error
ALE 35
COMM hardware error
ALE 36
Reserved
ALE 37
Reserved
ALE 38
Reserved
ALE 39
Reserved
ALE 40
Initial setup error
Communication
ALE 41
receive time out
Communication
ALE 42
receive error
Error communication
ALE 43
response address
Error communication
ALE 44
response command
Communication
ALE 45
parameter address
error
Communication
ALE 46
parameter content
error
Drive specification
ALE 47
error
Fast editing function
ALE 48
error
10-2
Fault Messages
Fault Name
Fault Messages
Fault Name
The character display on LCM is in error.
When parameter P8-09 is enabled, LED indicator is
abnormal.
When parameter P8-09 is enabled, the function key is
disabled.
When parameter P8-09 is enabled, the dynamical memory
(RAM) is abnormal.
The data memory (EEPROM) is abnormal.
Communication is in error during communication initial setup.
Communication initial setup has not completed yet.
Communication time out when receiving data (continuously
communicate over three times)
Checksum error when receiving data during communication.
Respond the error communication address.
Respond the error communication command.
Respond the error parameter communication address.
Respond the error parameter content.
The servo drive specification does not match when save and
write out parameter.
The function of static and dynamic auto-tuning is in error.
Fault Description
Fault Description
Revision January 2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents