7.3

Detailed Parameter Listings

Group 0: P0-xx
Monitor Parameters
P0 - 00★
VER

Firmware Version

Default: Factory setting
Applicable Control Mode: P/S/T
Unit: N/A
Range: N/A
P0 - 01★
ALE

Drive Fault Code

Default: Factory setting
Applicable Control Mode: P/S/T
Unit: N/A
Range: 1 ~ 20
Settings:
: Overcurrent (Note 1)
: Overvoltage (Note 2)
: Undervoltage (Note 2)
: Z Pulse shift (Note 3)
: Regeneration error (Note 1)
: Overload (Note 1)
: Overspeed (Note 1)
: Abnormal pulse control command (Note 1)
: Excessive deviation (Note 1)
: Serial communication error (Note 2)
: Encoder error (Position detector fault) (Note 3)
: Adjustment error (Note 1)
: Emergency stop (Note 2)
: Reverse (CWL) limit error (Note 2)
: Forward (CCWL) limit error (Note 2)
: IGBT temperature error (Note 2)
: Memory error (Note 4)
: Serial communication time out (Note 2)
: Motor type error (Note 2)
: Input power phase loss (Note 2)
Revision January, 2009
Chapter 7 Servo Parameters|ASDA-B Series
Communication Addr.: 0000H
Related Section: N/A
Communication Addr.: 0001H
Related Section:
Chapter 10
7-19