Analog Speed Command S-curve Filter

ASDA-B series servo drives also provide Analog Speed Command S-curve Filter for the smoothing in
response to a sudden analog input signal.
Speed (rpm)
3000
0
1
-3000
The analog speed command S-curve filter is for the smoothing of analog input signal and its function is
the same as the S-curve filter. The speed and acceleration curve of analog speed command S-curve
filter are both continuous. The above figure shows the curve of analog speed command S-curve filter
and the users can see the ramp of speed command is different during acceleration and deceleration.
Also, the users can see the difference of input command tracking and can adjust time setting by using
parameter P1-34, P1-35, P1-36 to improve the actual motor performance according to actual condition.
Analog Speed Command Low-pass Filter
Analog Speed Command Low-pass Filter is used to eliminate high frequency response and electrical
interference from an analog speed command and it is also with smoothing function.
Relevant parameters:
Accel / Decel Smooth Constant of Analog Speed
P1 - 06
SFLT
Command (Low-pass Filter)
Default: 0
Applicable Control Mode: S
Unit: ms
Range: 0 ~ 1000 (0: Disabled)
NOTE
1) If the setting value of parameter P1-06 is set to 0, it indicates the function of this parameter
is disabled and the command is just By-Pass.
Revision January, 2009
Chapter 6 Control Modes of Operation|ASDA-B Series
Analog speed command
2
3
4
Target Speed
5
6
7
Communication Addr.: 0106H
SFLT
Motor Torque
Time (sec)
8
9
Related Section:
Section 6.3.3
6-13