Chapter 6 Control Modes of Operation|ASDA-B Series
There are two turning modes of gain adjustment: Manual and Auto modes. The gain of ASDA-B series
servo drives can be adjusted by using any one of two tuning modes.
Manual Mode:
User-defined loop gain adjustment. When using this mode, all auto and auxiliary function will be
disabled.
Auto Mode:
Continuous adjustment of loop gains according to measured inertia automatically.
In Auto mode, if the users change the setting value of P2-31, the setting value of the parameters listed
in the Table 6.4 and 6.5 will also be changed.
Stiffness
Speed Loop
Setting
Responsive-
ness (Hz)
P2-31
0
10
1
5
2
20
3
25
4
30
5
35
6
45
7
55
8
65
9
80
A
100
B
120
C
145
D
170
E
205
F
250
6-16

PI Structure (P2-32)

Proportional
Proportional
Position Loop
Speed Loop
Gain P2-00
Gain P2-04
10
62
15
94
20
125
25
157
30
188
35
219
45
282
55
345
65
408
80
502
100
628
120
753
145
911
170
1068
205
1288
250
1570
Table 6.D
Low-pass
Filter Time
Speed Integral
Constant
Compensation
(Resonance
P2-06
Suppression)
P2-25
10
125
15
83
20
62
25
50
30
41
35
35
45
27
55
22
65
19
80
15
100
12
120
10
145
8
170
7
205
6
250
5
External Anti-
Interference
Gain P2-26
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0