Chapter 5 Parameters|VFD-S Series

5.1 Summary of Parameter Settings

: The parameter can be set during operation.

Group 0 User Parameters

Pr.
0-00
Identity Code of the AC Motor Drive
0-01
Rated Current Display of the AC
Motor Drive
0-02
Parameter Reset
0-03 Start-up Display Selection
0-04 Content of Multi-Function Display
0-05 User-Defined Coefficient K
0-06
Software Version
0-07
Password Input
0-08
Password Set
0-09
Memory Mode Selections

Group 1 Basic Parameters

Pr.
1-00
Maximum Output Frequency (Fmax)
1-01
Maximum Voltage Frequency (Fbase) d10.0 to d400 Hz
1-02
Maximum Output Voltage (Vmax)
1-03
Mid-Point Frequency (Fmid)
5-2
Explanation
Explanation
Settings
Read-only
Read-only
d09: All parameters are reset to
factory settings (50Hz,
220V/380V)
d10: All parameters are reset to
factory settings (60Hz,
220V/440V)
d0: Display the frequency command
value (LED F)
d1: Display the actual output
frequency (LED H)
d2: Multifunction display, see Pr.00-
04
d3: Display output current (LED A)
d4: Display forward/reverse
command (Frd/rEv)
d0: Display User-Defined Unit (u)
d1: Display Counter Value (C)
d2: Display Process Operation (1.tt)
d3: Display DC-BUS Voltage (
d4: Display output voltage (E)
d5: Display frequency commands of
PID (P)
d6: Display analog feedback signal
value (b) (%)
d7: Display output voltage
command (G)
d0.1 to d160
Read-only
d0 to d999
d0 to d999
d0 to d63
Settings
d50.0 to d400 Hz
230V series: d2.0V to d255V
460V series: d4.0V to d510V
d1.0 to d400 Hz
Revision August 2008, SE09, SW V2.61
Factory
NOTE
Setting
d #
d##.#
d0
d0
)
u
d0
d1.0
d#.#
d0
d0
d8
Factory
NOTE
Setting
d60.0
d60.0
d220
d440
d1.0

Advertisement

Table of Contents
loading