This chapter describes trial run and tuning procedure for servo drive and motor. Trial run, which is divided
into two parts, one part is to introduce the trial run without load, and the other part is to introduce trial run with
load. Ensure to complete the trial run without load first before performing the trial run with load. Tuning
procedure includes the tuning process, flowchart, and the relevant parameters of AutoMode (PI & PDFF)
mode and Manual mode
5.1

Inspection without Load

In order to prevent accidents and avoid damaging the servo drive and mechanical system, the trial run
should be performed under no load condition (no load connected, including disconnecting all couplings and
belts). Do not run servo motor while it is connected to load or mechanical system because the unassembled
parts on motor shaft may easily disassemble during running and it may damage mechanical system or even
result in personnel injury. After removing the load or mechanical system from the servo motor, if the servo
motor can runs normally following up the normal operation procedure (when trial run without load is
completed), then user can connect to the load and mechanical system to run the servo motor.
In order to prevent accidents, the initial trial run for servo motor should be conducted under no load conditions
(separate the motor from its couplings and belts).
Caution: Please perform trial run without load first and then perform trial run with load connected. After the
servo motor is running normally and regularly without load, then run servo motor with load connected. Ensure
to perform trial run in this order to prevent unnecessary danger.
After power in connected to AC servo drive, the charge LED will light and it indicates that AC servo drive is
ready. Please check the followings before trial run in order to find the problem and correct it in advance.
Doing this can avoid the damage to the servo drive and servo motor.
Item
Inspection before
operation
(Control power is not
applied)
Revision January 2009

Chapter 5 Trial Run and Tuning Procedure

Inspect the servo drive and servo motor to insure they were not damaged.
To avoid an electric shock, be sure to connect the ground terminal of servo drive
to the ground terminal of control panel.
Before making any connection, wait 10 minutes for capacitors to discharge after
the power is disconnected, alternatively, use an appropriate discharge device to
discharge.
Ensure that all wiring terminals are correctly insulated.
Ensure that all wiring is correct or damage and or malfunction may result.
Visually check to ensure that there are not any unused screws, metal strips, or
any conductive or inflammable materials inside the drive.
Never put inflammable objects on servo drive or close to the external
regenerative resistor.
Make sure control switch is OFF.
If the electromagnetic brake is being used, ensure that it is correctly wired.
If required, use an appropriate electrical filter to eliminate noise to the servo drive.
Ensure that the external applied voltage to the drive is correct and matched to the
controller.