Notch Filter Attenuation Rate
P2 - 24
DPH
(Resonance Suppression)
Default: 0
Applicable Control Mode: P/S/T
Unit: dB
Unit: Hz
Range: 0 ~ 32
Settings:
0: Disabled
Low-pass Filter Time Constant
P2 - 25
NLP
(Resonance Suppression)
Default: 20
Applicable Control Mode: P/S/T
Unit: 0.1ms
Range: 0 ~ 10000
Settings:
This parameter is used to set low-pass filter time constant of resonance suppression.
0: Disabled
P2 - 26
DST
External Anti-Interference Gain
Default: 0
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 511
Settings:
0: Disabled
7-46
Communication Addr.: 0218H
Related Section:
Section 6.3.7, P2-23
Communication Addr.: 0219H
Related Section:
Section 6.3.7, P2-32
Communication Addr.: 021AH
Related Section:
Section 6.3.7, P2-32