Figure 23: Dc Power Supply Faceplate For An Ex4600 Switch - Juniper EX4600 Series Hardware Manual

Hide thumbs Also See for EX4600 Series:
Table of Contents

Advertisement

EX4600 Switch Hardware Guide
152
power supply on the other side of the chassis. This configuration provides
the commonly deployed A/B feed redundancy for the system.
Secure the ring lug of the positive (+) DC power source cable to the V+ terminal
a.
on the DC power supply.
Secure the ring lug of the negative (–) DC power source cable to the V– terminal
b.
on the DC power supply.
Tighten the screws on the power supply terminals until snug using the screwdriver.
c.
Do not overtighten—apply between 5 in-lb (0.56 Nm) and 6 in-lb (0.68 Nm) of
torque to the screws.

Figure 23: DC Power Supply Faceplate for an EX4600 Switch

1—
Shunt negative input terminals (+RTN)
2—
Shunt positive input terminals (-48V)
3—
Terminal block
4—
Ejector lever
CAUTION:
The V+ terminals are shunted internally together, as are the
V- terminals. The same polarity terminal can be wired together from the
same source to provide an additional current path in a higher power
chassis. Do not connect the terminals to different sources.
5
5—
ESD grounding point
6—
Fault LED
7—
Output LED
8—
Input LED
Copyright © 2014, Juniper Networks, Inc.