Connecting DC Power to an EX4600 Switch

Copyright © 2014, Juniper Networks, Inc.
Figure 22: Connecting an AC Power Cord to an AC Power Supply in an
EX4600 Switch
1— Power cord retainer
If the AC power source outlet has a power switch, set it to the OFF (O) position.
6.
NOTE:
The switch powers on as soon as power is provided to the power
supply. There is no power switch on the device.
Insert the power cord plug into an AC power source outlet.
7.
If the AC power source outlet has a power switch, set it to the ON (|) position.
8.
Verify that the AC and DC LEDs on each power supply are lit green.
9.
If the amber fault LED is lit, remove power from the power supply, and replace the
power supply
(see"Removing a Power Supply from an EX4600 Switch" on page 169
). Do not remove the power supply until you have a replacement power supply ready:
the power supplies or a blank cover panel must be installed in the switch to ensure
proper airflow.
CAUTION:
Replace a failed power supply with a blank panel or new power
supply within 1 minute of removal to prevent chassis overheating.
AC Power Supply in an EX4600 Switch on page 23
AC Power Supply LEDs on an EX4600 Switch on page 194
The power supply in an EX4600 switch is a hot-removable and hot-insertable
field-replaceable unit (FRU). You can remove and replace it without powering off the
switch or disrupting switch functions.