Juniper EX4600 Series Hardware Manual page 96

Hide thumbs Also See for EX4600 Series:
Table of Contents

Advertisement

EX4600 Switch Hardware Guide
Related
Documentation
78
P
– LL = P
B
M
(13 dBm) – (0.5 dBm [HOL]) – ((5) * (0.5 dBm)) – ((2) * (0.5 dBm)) – ((2 km) *
(1.0 dBm/km)) – (1 dB [CRM]) = P
13 dBm – 0.5 dBm – 2.5 dBm – 1 dBm – 2 dBm – 1 dBm = P
13 dBm – 0.5 dBm – 2.5 dBm – 1 dBm – 2 dBm – 1 dBm = P
P
= 6 dBm
M
The calculated power margin is greater than zero, indicating that the link has sufficient
power for transmission. Also, the power margin value does not exceed the maximum
receiver input power. Refer to the specification for your receiver to find the maximum
receiver input power.
Calculating the EX Series Switch Fiber-Optic Cable Power Budget on page 76
Understanding EX Series Switches Fiber-Optic Cable Signal Loss, Attenuation, and
Dispersion on page 74
Pluggable Transceivers Supported on EX Series Switches
M
M
M
Copyright © 2014, Juniper Networks, Inc.