:SOURce:VOLTage:CONTrol:AFC[:STATe]

Syntax
:SOURce:VOLTage:CONTrol:AFC[:STATe] {ON|OFF|1|0}
:SOURce:VOLTage:CONTrol:AFC[:STATe]?
Description
Turns on/off the auto frequency control function
Parameter
ON or 1
OFF or 0(Preset
value)
Equivalent key
PN Menu -> DC Control Voltage -> Auto Freq Control -> AFC Status
SP Menu -> DC Control Voltage -> Auto Freq Control -> AFC Status
FP Menu -> DC Control Voltage -> Auto Freq Control -> AFC Status
TR Menu -> DC Control Voltage -> Auto Freq Control -> AFC Status
USER Menu -> DC Control Voltage -> Auto Freq Control -> AFC Status

:SOURce:VOLTage:CONTrol:AFC:TARGet

Syntax
:SOURce:VOLTage:CONTrol:AFC:TARGet <numeric>
:SOURce:VOLTage:CONTrol:AFC:TARGet?
Description
Sets/Reads the target frequency in the auto frequency control function
Parameter
When the E5052A is used stand-alone, or with the downconverter turned off
(Allowable setting range varies depending on whether the frequency offset is on or
off, the LO frequency within the frequency offset, and the conversion mode used in
the frequency offset)
Range
Preset value
Unit
Resolution
When the downconverter is turned on and the RF input is set to 'E5052A Direct'
(Allowable setting range varies depending on whether the frequency offset is on or
off, the LO frequency within the frequency offset, and the conversion mode used in
7
:SOURce:VOLTage:CONTrol:AFC[:STATe]
Description
Turn on the auto frequency control function mode
Turn off the auto frequency control function mode
<Numeric>
10M to 7G
1G
Hz
100m
SCPI Command Reference