:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:FREQuency

Syntax
:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:FREQuency {HZ|DHZ|PCT|PPM}
:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:FREQuency?
Description
Sets/Reads the frequency format
Parameter
HZ(Preset value)
DHZ
PCT
PPM
Equivalent key
TR Menu -> Format -> Frequency Format
:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:PHASe:PREFe
rence:OFFSet
Syntax
:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:PHASe:PREFerence:OFFSet <numeric>

:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:PHASe:PREFerence:OFFSet?

Description
Sets/Reads the offset value of the phase reference frequency
Parameter
Range
Preset value
Unit
Resolution
Equivalent key
TR Menu -> Setup -> Recalc Phase Reference -> Phase Ref. Offset

:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:PHASe:UNIT

Syntax
:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:PHASe:UNIT {DEG|RAD|GRAD}
:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:PHASe:UNIT?
Description
Selects phase format on transient measurement
7
:CALCulate:TR[1-1]:TRACe[1-4]:FORMat:FREQuency
Description
Set the frequency format to 'Hz'
Set the frequency format to 'ΔHz'
Set the frequency format to '%'
Set the frequency format to 'ppm'
<Numeric>
-25.6M to 25.6M
0
Hz
1m
SCPI Command Reference