04/SHOCK ABSORBER, SWINGARM
When the pressure gauge reaches the required value, turn control lever Damper
to Vacuum.
Guideline
3 bar
The pressure gauge drops to the required value.
0 bar
200269-10
When the pressure gauge reaches the required value, turn control lever Oil reser-
voir
to Vacuum.
5
Guideline
0 bar
The vacuum gauge drops to the required value.
8 mbar
200270-10
When the vacuum gauge reaches the required value, turn control lever Oil reser-
voir
to Equalize Pressure.
5
Guideline
8 mbar
The pressure gauge drops to the required value.
0 bar
200267-10
When the pressure gauge reaches the required value, turn control lever Damper
to Pressure.
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge increases to the required value.
3 bar
200268-10
When the pressure gauge reaches the required value, turn control lever Damper
to Vacuum.
Guideline
3 bar
The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the required value, activate the On/Off switch.
Guideline
200269-10
0 bar
The vacuum pump is switched off.
Slide O-ring
minus specified value).
Guideline
10 mm
Depth micrometer (T107S) (
Push the floating piston into the reservoir to the distance described above using the
special tool.
201626-10
to the end of the special tool by the specified value (distance
B