Replace Voice-Only Terminal With Voice/Data Terminal - AT&T Network Adapter 25 Installation And Maintenance Manual

Adtran network adapter product manual
Hide thumbs Also See for Network Adapter 25:
Table of Contents

Advertisement

Figure C-3. DS1 Network Interface Connections
Replace Voice-Only Terminal With
Terminal
1.
Using the Voice and Data Station Records
EQUIPMENT ROOM STATION CABLING" in section 2), find the jack
in the SIP adapter associated with the voice terminal that is to share
a cable with. a data terminal or personal computer.
2.
Remove the plug (leg of the octopus cable) from the modular jack of
the SIP adapter.
3.
Insert a Y plug adapter in the same modular jack of the SIP (see
"Make SIP Connections for Data Terminals and Computers" in
section 2).
4.
Insert the modular plug on the octopus cable into the voice side of
the Y adapter.
5.
Select an unused modular plug that is attached to a TN726 Data Line
CP (or, add a TN726 CP and its octopus cable if there are none).
6.
Insert the plug into the data side of the Y adapter.
7.
Document the change.
Install the appropriate ADU, following the procedures under "Install
8.
Terminals" in Section 2.
C-12
Voice/Data
Form (see "INSTALL