Out-Of-Building Voice Terminals (Tn742) - AT&T Network Adapter 25 Installation And Maintenance Manual

Adtran network adapter product manual
Hide thumbs Also See for Network Adapter 25:
Table of Contents

Advertisement

Off-Premises Stations (TN742, TN746B in R3V2)
An FCC-registered single-line terminal may
Station (OPS).
Note: Only the local telephone
interconnections for the OPS.
The connections between the network interface and the 700A Jacks are
described under "Connect Network Interfaces to TAE Jacks." (Only the TN742
CP supports this feature.)
1.
Trace the OPS pairs through the network interface to their termination
on the TAE.
Install secondary wiring protectors. (See Table 2-B.)
2.
3.
Cut down one end of a cable pair on the 700A and the other to a 858A
Adapter on the SIP.
4.
Connect an octopus cable to a TN742 circuit pack.
5.
Connect the octopus cable
6.
Document all connections.
Out-of-Building Voice Terminals
A single-line voice terminal may be located in another building in a campus
environment within a loop resistance of less than 1300 ohms (including the voice
terminal). These terminals require primary and secondary protection devices.
Only a TN742 CP can be used.
1.
At the remote location, connect the single-line terminal to a 103A
connecting block, using a modular telephone cord.
2. Using 4-pair inside wiring cable, connect the 103A connecting block to
primary and secondary protection devices. (See Table 2-B.)
3. Run the cable from the remote protection device to the System 25
equipment location.
be installed as an Off-Premises
can
company
legs to the adapter wired in Step 3 above.
TN746B in R3V2)
(TN742,
INSTALLATION
install the