AT&T Network Adapter 25 Installation And Maintenance Manual page 379

Adtran network adapter product manual
Hide thumbs Also See for Network Adapter 25:
Table of Contents

Advertisement

Administration Error Messages
APPENDIX F shows Basic Administration error codes and descriptions. The
Advanced Administration system uses different terminology. For additional
details about an error message in Basic Administration, press the "?" key.
The following table lists and describes error messages that can be displayed at
the SAT while administering the system. The table also includes possible
solutions for some of the error messages.
ERROR MESSAGE
AND DESCRIPTION
1000:
entry out of range must be
3-4 digits
1001:
incorrect entry
must be 0 with equipped
facility
1 0 0 2 : incorrect PDC
does not exist or used
i m p r o p e r l y
1003:
inappropriate request
incorrect mode
1 0 0 4 : incorrect entry or cabinet
number out of range
1005:
incorrect entry
slot number out of range
APPENDIX F:
POSSIBLE SOLUTION
Entered data must be a 3- or 4-digit
number or 0.
This error occurs you try to change
the terminal code type. EXAMPLE:
Go to MENU 2 (PDC). Go to any
PDC target value and type
ACTION = 1, you see
DATA = terminal code
type 304 etc.
(Try to change the DATA value to
another terminal code type) DATA =
305 you get error 1001: (You have to
O the terminal type code if you want
to change its value)
Could be existing PDC number
Go to MENU 8 (search)
ACTION = 1 DATA= 11
Hit c to continue to search for
assigned PDCs
The entered mode does not exist.
Cabinet-Slot-Port (CSSPP) SS must
be a number from 1 to 3
Cabinet-Slot-Port (CSSPP) SS must
be a number from 1 to 12
F-1