MAINTENANCE
A typical error record from the Permanent System Alarms and Transient
System Errors table is as follows:
PORT
BOARD FIRST
NUMBER CODE
10400
ZTN130
Interpret this record as follows:
"Port Number" 10400
specifying the location
(1-3), the next two digits indicate the slot within the cabinet
cabinet
(01-12),
and the last two digits indicate the port number on the CP in
the slot
(01-08).
"Board
Code" ZTN130 is the CP on which the error occurred (or
that is associated with the error if this is an off-board error).
"First Occurred" 23/12:30 is the date and time of the first
occurrence of this error. The date is assumed to be the current year
and month. A 24-hour clock is used.
"Last Occurred" 30/01:56, is the date and time of the last
of this error. The date is assumed to be the current year
A 24-hour clock is used.
"Count" 1 is the number of times this particular error has
"Name" Port Board Missing But Administered is a description of the
nature of the error. Descriptions are self-explanatory.
4-28
PERMANENT SYSTEM ALARMS
L A S T
OCCURRED OCCURRED
30/01:56
23/12:30
is the 5-digit port identification number
of the error. The first digit indicates the
COUNT NAME
1
Port Board missing
But Administered
occurrence
and month.
occurred.