MAINTENANCE
ERROR MESSAGE
AND DESCRIPTION
Unrecognized
(STARLAN Interface CP) This
isolated transient
error is an
condition.
User Forced Warm Start: System
was warm started through the
SAT.
Warm Start:
System was restarted for some
reason; translations are okay.
Wink Too Short For Valid Signal:
For a delay dial or wink start
outgoing trunk, if the wink from
the far end is less than the
minimum 100 ms, this error is
generated. The tie trunk remains
waiting for a valid signal.
Work Cycle Interrupt Test Failed:
interrupt problem.
Work cycle
System most likely is stopped.
4-46
POSSIBLE SOLUTION
Command:
Recoverable; no action required.
Recoverable; no action required.
Power supply may be out of
regulation (see Figure 4-2). Check
remaining errors
tables for associated problems.
Check equipment at far end to
ensure that it is working and
translated properly per Figure 4-3.
Try to warm start the system
through the SAT. If the problem
persists, check or replace the
CPU/Memory CP.
in the alarm