N Mlx Voice And Terminal Adapter Data Stations - AT&T MERLIN LEGEND Release 3.1 Installation Manual

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 3.1:
Table of Contents

Advertisement

MLX Voice and Terminal Adapter Data Stations
MLX Voice and Terminal Adapter
Data Stations
Figure 6–4 shows the equipment configuration for MLX voice and terminal
adapter data station.
The configuration shown in Figure 6–4 is for asynchronous terminal adapter
data transmission. For information on setting up synchronous terminal adapter
data stations, see "Video Conferencing Data Stations," later in this chapter.
The maximum cord length from the terminal adapter to the telephone is 80 ft.
(24.38 m).
Setting Up
To set up an MLX voice and terminal adapter data station, follow the steps
below:
1 Use an EIA-232-D cable to connect the serial port on the data terminal to
the terminal adapter.
If the data terminal that has both COM1 and COM2 connectors, make sure
you use the one designated for data transmission. See the customer's system
manager if you are not sure.
2 Make sure the terminal adapter option settings for parity and speed are
compatible with the data terminal. (Speed is synchronized automatically
if the factory setting has not changed.)
If you are not sure about the speed and parity of the data terminal, see the
customer's system manager or the documentation packaged with the terminal
adapter and data terminal.
3 Plug the other end of the EIA-232-D cable into PORT 1 on the terminal
adapter.
4 Plug the WP90110-L7 power supply cord into the POWER receptacle on
the terminal adapter.
6–12