INSTALLATION
SIP
Make
Connections to Cabinet for MET Sets
Follow the same procedure as for 7300H Series terminals to connect MET set
SIP appearances to the appropriate CPs as outlined below:
Connect the 25-pair connector to a TN735 CP
Attach a cable label to the octopus cable 25-pair connector and flag-
type tie wrap
Run the cable 10 the 50A Fanning Strip
Plug cable ends into the appropriate SIP adapters
Complete the Voice and Data Station Records Form.
Note:
Each TN735 CP supports only four MET sets. Therefore, only the first
four modular plugs on each octopus cable should be connected to the
SIP adapters.

Make SIP Connections to Cabinet for Single-Line Sets

Follow the same procedure as for 7300H Series terminals to conned single-line
voice terminal SIP appearances to the appropriate CPs as outlined below:
Connect the 25-pair connector of the octopus cable to a ZTN78 CP
Attach a cable label to the octopus cable 25-pair connector and flagtype
tie wrap
Run the cable to the 50A Fanning Strip
Plug the cable ends into the appropriate
Voice and Data Station Records Form.
For extended, off-premises, and out of-building
procedure as above, except connect the octopus cable to a TN742/TN746 CP.
For Connection to a TN746 CP, follow the procedure outlined below.
Attach the connector marked "0' of the 853B adapter to a TN746 CP
("0")
2-74
adapters, and complete the
stations, follow the same
November 1995