Ricoh FT6645 Manual page 167

Hide thumbs Also See for FT6645:
Table of Contents

Advertisement

23 April 1993
1
SP ADJUSTMENT
PAGE 9
Item
Selects the exposure lamp voltage
when auto process control is disabled
or RAM is cleared. (0.5 V/step)
Default: 65.0 V
Adjusts the transfer current.
(1µA/step)
Default: 40 µA
Initializes the by-pass paper size
sensor.
Function
4-13
SERVICE PROGRAM MODE
Note
Enter the data by using the number
keys, then touch
Adjust
Standard Data: 40 mA
Enter the data by using the number
keys, then touch
Adjust
Procedure:
1. Set the by-pass table side fence to
the A4/81/2 x 11 position, then touch
the
key
Enter
2. Set the by-pass table side fence to
the A6/41/4 x 51/2 position, then
touch the
Enter
Perform this mode when the by-pass
paper size sensor is replaced.
.
.
.
key
.

Advertisement